6.7.10 PULSE Mode

PULSE transient mode provides a quick and easy way to enter repetitive pulsed output
events. This applies to AC voltage and or Frequency. A sample of a PULSE transient
definition is shown in the screen capture below.
The parameters that define a PULSE transient are dependent of each other so changing one
may force another to change. The semantics used for setting PULSE transients is as follows:
Parameter
RAMP
WIDTH
PERIOD
DUTY
The DUTY cycle is determined by the other three parameters as in:
DUTY = WIDTH x 100 / PERIOD
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Description
Up or down ramp time
Duration of pulse including rising and failing ramp times
Total time duration for a single pulse
Duty cycle of the pulse