Pacific Power Source LMX Series Operation Manual page 279

Programmable ac power source
Table of Contents

Advertisement

Query Syntax
Description
Parameters
Parameter Format
Query Example
Query Syntax
Description
Parameters
Parameter Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]IMPEDance:L[:LIMit]:MAXimum?
This command return the maximum allowable setting value for the L
component of the output impedance.
None
N/A
IMPED:L:MAX?
0.00005000
[SOURce:]IMPEDance:L[:LIMit]:MINimum?
This command return the minimum allowable setting value for the L
component of the output impedance.
None
N/A
IMPED:L:MIN?
0.00000000
[SOURce:]IMPEDance:MODE
This command sets the programmable impedance mode to either
Real-Time mode (0) or RMS Mode (1). See page 154 for a description
of both impedance modes.
0
Real mode.
1
RMS mode.
Note: To change programmable impedance modes, the output of
the power source must be turned OFF first. Trying to change
modes while the output is ON will result in an error message.
< 0 | 1 >
<b>
IMPED:MODE 1
[SOURce:]IMPEDance:MODE?
<b>
IMPED:MODE?
1
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 279 of 463