4.11 Dimensions & Weight by Model
MODEL
105LMX
108LMX
112LMX
140LMX
160LMX
305LMX
308LMX
312LMX
320LMX
345LMX
360LMX
4.11.1 Rack Handles
The front panel mounted rack handles are intended for use in installing or removing the
power source from a 19" instrument cabinet only.
These handles should not be used to carry or move the power source to a different location.
Always use a suitable cart for lift to move the power source.
4.11.2 Rack Mount Slides
The chassis of the LMX-Series Power Source is designed to accept slide rails. These can be
provided as a cost option. For more information, contact your local sales representative or
the Pacific Power Source Sales Office.
Do not install or remove the power source with less than two persons in view of the unit's
weight. It is strongly recommended to use a suitable mechanical lift to install/remove the
unit in a cabinet.
4.12 Environmental
ENVIRONMENTAL
Cooling
Maximum Air flow by Model:
105LMX, 108LMX, 305LMX, 380LMX
140LMX, 160LMX, 345LMX, 360LMX
Operating Temperature
Storage Temperature
Humidity
Altitude (max.)
7
Front panel width. Chassis width is 16.75" / 426 mm for models < 2.5kVA or 17" / 432 mm for 2.5kVA & higher models.
8
Measured from back side of front panel to front panel. Excludes terminal block depth.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
HEIGHT
WIDTH
5.25" / 134 mm
19" / 483 mm
5.25" / 134 mm
19" / 483 mm
5.25" / 134 mm
19" / 483 mm
14" / 356 mm
19" / 483 mm
14" / 356 mm
19" / 483 mm
5.25" / 134 mm
19" / 483 mm
5.25" / 134 mm
19" / 483 mm
5.25" / 134 mm
19" / 483 mm
8.75" / 222 mm
19" / 483 mm
14" / 356 mm
19" / 483 mm
14" / 356 mm
19" / 483 mm
112LMX, 312LMX
320LMX
LMX SERIES® OPERATION MANUAL
SECTION 4: Technical Specifications
DEPTH
7
8
23" / 584 mm
23" / 584 mm
23" / 584 mm
23.5" / 597 mm
23.5" / 597 mm
23" / 584 mm
23" / 584 mm
23" / 584 mm
23.12"/587 mm
23.5" / 597 mm
23.5" / 597 mm
Fan Cooled, Front and/or Side air intake, rear exhaust
100 CFM
200 CFM
300 CFM
600 CFM
0 to 55 °C / 32 to131 °F
-20 to 70 °C / -4 to 158 °F
< 95%, non-condensing
2000 m / 6561 feet
WEIGHT w/o & [w T]
70 lbs / 32 kg [97 lbs / 44 kg]
70 lbs / 32 kg [97 lbs / 44 kg]
80 lbs / 36 kg
185 lbs / 84 kg
195 lbs / 88 kg
74 lbs / 34 kg [100 lbs / 45 kg]
74 lbs / 34 kg [100 lbs / 45 kg]
80 lbs / 36 kg
150 lbs / 68 kg
190 lbs / 86 kg
195 lbs / 88 kg