Pacific Power Source LMX Series Operation Manual page 282

Programmable ac power source
Table of Contents

Advertisement

The impact of inserting the initial value (ON) or not (OFF) is illustrated in the figure below.
The top sequence shows a STEP transient repeated 3 times with STEP:INIT set ot
OFF. The output will not return to the initial output setting between repetitions.
The bottom sequence is the same STEP transient with STEP:INIT set to ON. Each
repeat will start from the initial set value so each repititon produces the same
output levels.
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]STEP:DWELL <time>, <opt>
This command sets the dwell time of the step in seconds
Minimum time set value allowed is 0.0001 sec. (0.1 msec)
Time in seconds, Option: < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr2>, <cr>
STEP:MODE:DWELL 10, SAT
[SOURce:]STEP:MODE?
<nr2>
STEP:MODE:DWELL?
10.0000, SAT
[SOURce:]STEP:DWELL:MINimum?
This command returns lowest permissible set value for the STEP
dwell time setting.
<nr2>
STEP:DWELL:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 282 of 463