[SOURce:]CURRent:PROTect:LEVel
This command sets the programmable current trip level for all
phases. The value set cannot exceed the maximum current capability
of the power source as returned by the
"[SOURce:]CURRent:LIMit#:MAX?" command.
If the load current exceeds the current trip set point, the source will
turn off its output after the "CURRent:PROTect:TOUT" delay time
outs and generate a fault message.
0.00 – MAX
<nr2>
CURR:PROT:LEV 24.0000
[SOURce:]CURRent:PROTect:LEVel?
<nr2>
CURR:PROT:LEV?
24.0000
[SOURce:]CURRent:OVerload
This command turns the overload current mode on or off
[ 0 | OFF | 1 | ON ]
<b>
SOUR:CURR:OV ON
[SOURce:]CURRent:OVerload?
<b>
CURR:OV?
1
[SOURce:]IPROTect:STATe
This command turns the current protection mode on or off
[ 0 | OFF | 1 | ON ]
<b>
IPROT:STAT ON
[SOURce:]IPROTect:STATe?
<b>
IPROT:STAT?
1
[SOURce:]IPROTect:TRIPped?
This command returns the current protection state. If the peak
current protection has been tripped, a 1 is returned.
<b>
IPROT:TRIP?
0
LMX SERIES™ OPERATION MANUAL