6.6.2
LIST Parameters
The following parameters are available in each transient list step.
PARAMETER
#
Ramp
Frequency
Voltage AC
Dwell
Note 1: Range may differ on models with Transformer (T) option
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Range
1
1 - 199
0.1 –
10,000,000
15 – 5000
0 – 135
1
0.1 -
10,000,000
Table 6-7: Available Transient List Parameters
LMX SERIES™ OPERATION MANUAL
SECTION 6:
Unit
Description
-
Displays the row number in the
transient table. These numbers are
generated automatically.
msec.
Ramp time to slew from existing set
point to new set point value. Applies
to both Frequency and Voltage.
If previous set value is the same as
new value, the value is not slewed
but rather stays at the same value for
the duration of the ramp time.
Hz
New frequency value
V rms
New AC voltage value
msec.
Dwell time. At the end of the ramp
time, the new set values remain in
effect during the dwell period. At the
end of the dwell time, the next list
entry (if any) will be executed.
Front Panel Operation
Page 121 of 463