Error Source
Code
Front panel
37
Front panel
42
Front panel
47
Front panel
48
Front panel
51
Front panel
53
Front panel
54
Front panel
56
Front panel
57
Front panel
58
Front panel
59
Front panel
60
Front panel
64
Front panel
65
Front panel
66
Front panel
67
Front panel
68
Front panel
69
Front panel
70
Front panel
72
Front panel
73
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
Error
Interface response packet
out of space.
Error
Memory in use was
removed.
Error
Front panel is shutting
down.
Error
Fault state cannot be
automatically reset.
Error
The command cannot be
executed in auxiliary unit.
Error
Error during firmware
update.
Error
Calibration coefficient
cannot be negative.
Error
Waveform name is not
available.
Error
Waveform file is not
available.
Error
Waveforms lengths are
different between
controllers.
Error
Unit does not exist.
Error
Cannot read ambient
temperature
Error
Unexpected reset.
Error
Front panel is in passive
mode.
Error
Invalid host name.
Error
DC voltage set point
cannot change due to
waveform saturation.
Error
AC voltage set point
cannot change due to
waveform saturation.
Error
Maximum user limit is
lower than set point.
Error
Minimum user limit is
higher than set point.
Error
Minimum limit is higher
than maximum.
Error
Maximum limit is lower
than minimum.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
Firmware Update Error.
Update may have failed
Negative Calibration
Coefficients are not
allowed
Waveform name
requested does not exist
Waveform register
selected is empty
Waveforms lengths are
not equal between three
phases
Unit selected cannot be
found
Inverter controllers were
reset
Passive Mode. Front
panel is most likely an
auxiliary unit
Host name requested is
invalid
Setting conflict.
Waveform data and DC
setting or in conflict
Setting conflict.
Waveform data and AC
setting or in conflict
Setting conflict. Set point
exceeds upper user limit
Setting conflict. Set point
is below lower user limit
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Setting conflict. Max.
User Limit must be higher
than Min. User Limit
Resolution
Check for correct
firmware image file and
version.
Make sure cal coefficients
are positive values
Use existing waveform
name from waveform
library
Download valid
waveform data to
selected register
Check waveform data for
correct length
Try recycling power. If
error persists, contact
customer service
Try recycling power. If
error persists, contact
customer service
Check parallel
configuration
Try recycling power. If
error persists, contact
customer service
Adjust DC setting or
waveform to resolve
conflict
Adjust AC setting or
waveform to resolve
conflict
Adjust setting or user
limit
Adjust setting or user
limit
Adjust User Limits
Adjust User Limits