Error Source
Code
Front panel
101
Front panel
102
Front panel
103
Front panel
104
Front panel
105
Front panel
106
Front panel
109
Front panel
110
Front panel
111
Front panel
115
Front panel
116
Front panel
117
Front panel
118
Front panel
119
Front panel
120
Front panel
121
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Category
Error Message
Error
AC voltage set point
cannot change due to
user limit.
Error
DC voltage set point
cannot change due to low
range.
Error
AC voltage set point
cannot change due to low
range.
Error
Waveform change in
progress.
Error
Error changing service
name
Error
Error getting service
name
Error
Transient step mode not
available on UPC
compatible mode.
Error
System is about to
reboot.
Error
Cannot reboot system.
Error
Unable to renew the
DHCP lease. Changing to
Auto-IP mode.
Error
Failed starting firmware
update.
Error
Unable to execute this
action with output
enable.
Error
Frequency set point
cannot change due to
waveform saturation.
Error
Frequency set point
cannot change due to
user limit.
Error
Frequency not allowed in
"DC mode".
Error
Waveform set point
cannot change due to
waveform saturation.
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Possible Cause
Setting conflict. Setting
outside of User Limits
Setting conflict. Setting
outside of User Limits
Setting conflict. Setting
outside of User Limits
Waveform change in
progress
Internal Service Error.
Could not change service
Internal Service Error.
Could not get service
name
Setting conflict. Step
mode only supported in
LMX mode.
Warning, Reboot
imminent
Soft reboot failed. Front
panel could not reboot
itself.
LAN Error. IP address
lease from DHCP expired
Firmware Update Error.
Unable to start firmware
update
Setting conflict.
Requested action not
possible with output ON
Setting conflict. In
extended voltage range,
frequency range is
restricted. Max peak
voltage is reduced
outside this range and if
there is a DC offset
programmed, the peak of
the voltage exceeds the
max. limit.
Setting conflict.
Frequency set point
outside User Limits
Setting conflict. No
frequency setting applies
in DC mode
Setting conflict. The crest
factor of the waveform
selected would result in a
peak voltage that exceeds
the max peak voltage
supported. Or combined
AC peak + DC
Resolution
Check setting
Check setting
Check setting
Wait
Try recycling power. If
error persists, contact
customer service
Try recycling power. If
error persists, contact
customer service
Switch to LMX mode or
use Segments
Wait
Try recycling power. If
error persists, contact
customer service
Renew IP lease of use
Auto IP mode
Check for correct
firmware image file and
version.
Turn output OFF
Reduce programmed
RMS and/or DC value.
Change User Limits or
frequency setting
Change to AC or AC+DC
mode
Reduce waveform crest
factor ratio or reduce
programmed RMS and/or
DC value.
Page 442 of 463