Pacific Power Source LMX Series Operation Manual page 364

Programmable ac power source
Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
RESET STATE
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Description
Returned Data Format
Query Example
Query Format
Description
Returned Data Format
Query Example
Command Syntax
Description
Parameters
Parameter Format
Command Syntax
Description
Parameters
Parameter Format
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
*RST
RESET. The *RST command (reset) has the same effect as an IEEE-488
Device Clear bus command but can be used over the RS232C, USB or
LAN interface as well. This command resets the unit to its power on
default state.
None
n/a
FORM
3
VOLT:AC
0.0000
VOLT:DC
0.0000
CURR:AC
41.6667
CURR:DC
20.8333
*SRE <nr1>
Before reading a status register, bits must be enabled. This command
enables bits in the service request register. The current setting is
saved in non-volatile memory.
0-255
<nr1>
*SRE 255
*SRE?
Reads the current state of the service request enable register. The
register is cleared after reading it. Refer to section 8.12 for register
bit values.
<nr1>
*SRE?
255
*STB?
Status Byte Query. The *STB? query returns the contents of the
status byte register (STB). After this query, the content of the STB
register is reset. Refer to section 8.12 for register bit values.
<nr1>
*STB?
4
*TRG
Triggers pending operation.
None
n/a
*WAI
Prohibits the instrument from executing any new commands until all
pending overlapped commands have been completed.
None
n/a
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
VOLT:MODE
COUPLING
RANGE
AC
DC
AC
Page 364 of 463