Pacific Power Source LMX Series Operation Manual page 287

Programmable ac power source
Table of Contents

Advertisement

Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Query Syntax
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]STEP:VOLTage[:AC][:INITial]# < nr2 >, <cr>
[SOURce:]STEP:VOLTage[:AC][:INITial]#
Voltage phase A, OPT: Voltage phase B, OPT: Voltage phase C, OPT
This command sets the initial STEP voltage for selected phase # or for
all phases if phase reference is omitted.
Note: If you get the following error, check the STEP:MODE setting as the
parameter you are trying to program is the depending one.
Execution error: Not allowed command with the current
configuration.
Either set one of the othe STEP parameters or change the MODE.
Note: If you get this error, check the min or max range for this parameter.
Parameter above maximum unit scope.
Voltage , < NORmal | SATurate >
Default is NORmal if optional second parameter is omitted.
<nr2>, <cr>
STEP:VOLT1 230.00, SAT
[SOURce:]STEP:VOLTage[:AC][:INITial]#?
<nr2> | <nr2>,<nr2>,<nr2>
STEP:VOLT1?
230.0000
[SOURce:]STEP:VOLTage[:AC][:INITial]#:MINimum?
This command returns the minimum permissible set value for the
initial STEP voltage for selected phase # or for all phases if phase
reference is omitted
<nr2>
STEP:VOLT1:MIN?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:VOLTage[:AC][:INITial]#:MAXimum?
This command returns the maximum permissible set value for the
initial STEP voltage for selected phase # or for all phases if phase
reference is omitted
<nr2>
STEP:VOLT1:MAX?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
[SOURce:]STEP:VOLTage[:AC][:INITial]#:DEFault?
This command returns the default set value for the initial STEP
voltage for selected phase # or for all phases if phase reference is
omitted
<nr2>
STEP:VOLT1:DEF?
Query return values for MINimim, MAXimum and DEFault are dependent on
MODE and interdependent parameter value settings
LMX SERIES™ OPERATION MANUAL