AUTO RMS Function – Transients" for further details.
Cycle Reset
The soft keys on the TRANSIENT SETTINGS screen are listed in the table below
SOFT KEY
-
-
-
-
Back (SK5)
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
When enabled, the CYCLE RESET mode will cause repeated
executions of the transient as determined by the repeat
count or the continuous execution setting to re-sync to the
start phase angle set for the start of each transient. When
disabled, repeats of the transients start immediately after
the previous execution completes with no resync. With
Cycle Reset on, there may be up to one period of the AC
frequency of delay added between successive runs.
Note: In UPC Compatibility mode, Cycle Reset is default on.
Description
Return to previous screen
Table 6-26: Available TRANSIENT SETTINGS screen soft keys
LMX SERIES™ OPERATION MANUAL
Front Panel Operation
SECTION 6:
Page 104 of 463