SYSTem:DIO:INput[n]:FALLing <cr>
SYSTem:DIO:INput[n]:RISing <cr>
Sets the SCPI command to be executed at the rising or falling event of
that digital input [n]. n = 1, 2 or 3.
SPCI command string
<cr>
SYST:DIO:IN1:FALL "OUTP 0"
SYST:DIO:IN1:RIS "OUTP 1"
These settings will enable the output at the rising edge of the pulse
and disable it at the falling edge.
SYSTem:DIO:INput[n]:FALLing?
SYSTem:DIO:Input[n]:RISing?
<cr>
SYST:DIO:IN1:RIS?
OUTP 1
SYST:DIO:IN1:FALL?
-
SYSTem:DIO:INput[n]:FILtersize <nr1>
Defines the time in ms (milliseconds) that the digital input has to
keep the state after a transition in order to generate the event.
If filtersize is zero, then the event is immediately generated,
otherwise the specified time will prevent short pulses from
generating events. This is useful in noisy environments and also if the
digital signal is controlled by a switch or a mechanical actuator.
0 – 1000
<nr1>
SYST:DIO:IN1:FIL 8
SYSTem:DIO:INput[n]:FILtersize?
<nr1>
SYST:DIO:IN1:FIL?
8
SYSTem:DIO:INput[n]:FILtersize:DEFault?
Returns the default filter size value.
<nr1>
SYST:DIO:IN1:FIL:DEF?
0
SYSTem:DIO:INput[n]:FILtersize:MAXimum?
Returns the maximum allowed filter size value.
<nr1>
SYST:DIO:IN1:FIL:MAX?
1000