Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Command Syntax
Description
Parameters
Parameter Format
Example
Query Format
Returned Data Format
Query Example
Query Syntax
Description
Query Example
Query Syntax
Description
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]PROTect[:RMS]:POWer:LEVel:MINimum?
This command returns the minimum true power protection level
setting.
PROT:POW:LEV:MIN?
0.000
[SOURce:]PROTect[:RMS]:POWer:LEVel:MAXimum?
This command returns the maximum true power protection level
setting.
PROT:POW:LEV:MAX?
41.667
[SOURce:]PROTect[:RMS]:POWer:LEVel:DEFault?
This command returns the default true power protection level
setting. This value will be a function of the power source model.
PROT:POW:LEV:DEF?
41.667
[SOURce:]PROTect[:RMS]:POWer:TDELAY <DELAY>
This command sets the true power protection trip delay time. Setting
is in multiples of 100 msec so 5 equals 500 msec.
< LEVEL >
<nr2>
PROT:POW:LEV 5
[SOURce:]PROTect[:RMS]:POWer:TDELAY?
<b>
PROT:POW:TDELAY?
5.000
[SOURce:]PROTect[:RMS]:POWer:TDELAY:MINimum?
This command returns the minimum true power protection trip delay
time setting.
PROT:POW: TDELAY:MIN?
0
[SOURce:]PROTect[:RMS]:POWer:TDELAY:MAXimum?
This command returns the maximum true power protection trip delay
time setting.
PROT:POW: TDELAY:MAX?
3000