Pacific Power Source LMX Series Operation Manual page 307

Programmable ac power source
Table of Contents

Advertisement

Query Syntax
Description
Parameters
Parameter Format
Description
Returned Data Format
Query Example
Query Syntax
Description
Parameters
Parameter Format
Description
Returned Data Format
Query Example
Query Syntax
Description
Parameters
Parameter Format
Description
Returned Data Format
Query Example
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
[SOURce:]PULSe:PROGress?
>>> Alias for PROGram:TRANsient:PROGress command. <<<
This query command returns the status of the step being executed.
None
n/a
Query returns the step transient execution state as either RUN, STOP,
PAUS, STEP or REST
<cr>
The response is a comma-separated value string representing:
PROGRESS, CURRENT SEGMENT PROGRESS, CURRENT SEGMENT, CURRENT
SEGMENT TIME, TOTAL TIME, TOTAL SEGMENTS, REPEAT TIME COUNTER
PULS:PROG?
1, 45, 2, 1.2300, 2.0000, 4, 5
[SOURce:]PULSe:CHECK?
This query command returns the result of a check on the
programmined pulse parameters to determine if they are ok to run.
None
n/a
Query returns result of PULSE parameters integrity check
<cr>
The response is either OK or if not, a string containing the error.
PULS:PROG?
OK
[SOURce:]PULSe:ALL?
This query command returns a comma-separated values string of the
entire pulse parameters, settings, and limits. Each set value is
preceded by a tag identifying the parameter. This same data
structure is used for front panel display and by the web server. The
advantage is that this commands returns all pulse related information
using just one query command.
None
n/a
Returns complete PULSE setup as a comma separed value string.
<cr>
PULS:ALL?
form,3,loaded,0,status,0,progress,0,current element progress,0,current
element,0,current element time,0,total time,0,total elements,0,repeat
times,0,count,1,count max,65535,count min,0,dcycle,50.0000,dcycle
max,100.0000,dcycle max,0.0000,period,0,period max,50000,period
min,0,width,0,width max,50000,width min,0,ramp,0,ramp max,0,ramp
min,0,mode,0,mode max,2,mode min,0,frequency,60.000,frequency
min,15.000,frequency max,1200.000,frequency min reason,1,frequency max
reason,2,waveform all,1,waveform all exist,1,waveform a,1,waveform a
exist,1,waveform b,1,waveform b exist,1,waveform c,1,waveform c
exist,1,waveform max,200,waveform min,1,voltage ac all,0.000,voltage ac all
max,300.000,voltage ac all min,0.000,voltage ac all max reason,2,voltage ac all
min reason,0,voltage ac a,0.000,voltage ac a max,300.000,voltage ac a
LMX SERIES™ OPERATION MANUAL
Remote Control Programming
SECTION 8:
Page 307 of 463