4.5
Configuring a key filter for HMI software
To prevent unwanted interruption of the HMI software while it is running, you can specify that
certain keystrokes will be filtered out and thus ignored.
This key filter is not activated in the delivery condition. You can activate the key filter and
individually select which of the 20 filterable keystrokes will be ignored. You cannot configure
any additional keystrokes to be filtered.
Precondition
● The Windows 7 Service Desktop is active
● Hidden directories are shown
Procedure
To configure the key filter, proceed as follows:
1. Switch to the template directory:
2. Save a copy of the template
3. In the new file (e.g.
4. Save your file.
Example: Activating the key filter but allowing use of the NUM-lock key.
This example activates the key filter (
keystrokes except the NUM-lock key.
KEYB_FILTER
KeySequencesEnable = 1
SeqActive_19= 0
In the adapted file in the user directory (e.g.
section name
other settings and values are in taken over from the template.
PCU Base Software (IM10)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
See also: Directory structure and file conventions (Page 11).
C:\ProgramData\Siemens\MotionControl\siemens\System\etc\
The settings can be viewed in the template
C:\ProgramData\Siemens\MotionControl\user\System\etc\
C:\ProgramData\Siemens\MotionControl\addon\System\etc\
C:\ProgramData\Siemens\MotionControl\oem\System\etc\
...\addon\System\etc\pcuhwsvc.ini
section name
[KEYB_FILTER]
All data and keys that do not occur in your file are automatically taken over from the
template in the
Siemens
See also: Directory structure and file conventions (Page 11).
[KEYB_FILTER]
Installing and configuring updates and automation software
pcuhwsvc.ini
to one of the user directories:
pcuhwsvc.ini
and the keys that are to differ from the template.
directory.
KeySequencesEnable = 1
Section name (mandatory):
Activate key filter
Do not filter NUM-lock key
...\addon\System\etc\
is mandatory as well as the settings that you want to adapt. All
4.5 Configuring a key filter for HMI software
.
), delete all data except for the
) and filters all possible
) therefore only the
45