Initial commissioning
2.2 Install the PCU Base Software attended
2.2
Install the PCU Base Software attended
If you have connected to the PCU 50.5 directly to the operator panel front or screen, you can
complete installation of the PCU Base Software and Windows 7 attended. For this, user
entries are required during installation in order to set up the Windows administrator account,
for example.
Alternately, you can use unattended installation (Page 17) in which case you define the
necessary user entries in an answer file (unattend.xml) before switching on the PCU 50.5.
Precondition
You can connect an operator panel front or screen and keyboard directly to the PCU 50.5.
Procedure
To perform attended installation of the PCU Base Software, proceed as follows:
1. Switch on the PCU 50.5.
The installation wizard guides you through the necessary steps.
2. During installation, create a Windows administrator account. You can create additional
user accounts in the Control Panel later. See also: Managing user accounts (Page 22).
3. Complete installation.
Result
Installation of the PCU Base Software with Windows 7 is performed. After attended
installation, you must activate the PCU Installer manually (Page 51).
16
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
PCU Base Software (IM10)