Siemens SINUMERIK 840D sl Commissioning Manual page 1032

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuration of the system
3.9 Configuring the SITOP UPS module for use with the PCU Base Software
3.9.1
SITOP modules for the PCU 50.5
Suitable SITOP UPS modules
SITOP UPS modules can continue operation of the PCU 50.5 temporarily if a power failure
occurs and/or shut down the system properly.
In conjunction with the PCU Base Software, all specific applications are taken into account
(e.g. HMI software) with component
Safe shutdown after a power failure of the delivery condition of the PCU 50.5 takes
approximately 20 seconds. For a typical power consumption of approx. 60 W, a capacitor-
buffered UPS with an energy storage device of 7.5 kW is recommended for a PCU 50.5. If
longer buffer times are required, then several expansion modules can be connected in a
cascade connection.
Example of a compatible SITOP UPS module:
SITOP 500S (15 A / 2.5 kWs capacitor)
MLFB: 6EP1933-2EC41
Further information
Information about available SITOP UPS modules is given in the catalog or in the Internet:
● Catalog KT 10.1 Power supply SITOP
● SIEMENS Industry Mall > 24 V DC Uninterruptible Power Supplies
(https://eb.automation.siemens.com/mall/en/US/Catalog/Products/7010117)
Note
Information about the test environment for machine OEMs
The "SITOP UPS" function has been tested in the standard configuration with the Base
Software. When installing add-on or OEM software components, you must check the
shutdown procedure of the entire system and adapt the factory settings.