Siemens SINUMERIK 840D sl Commissioning Manual page 1048

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Installing and configuring updates and automation software
4.5 Configuring a key filter for HMI software
Template of the key filter in the delivery condition
The template is located in
directory:
Do not overwrite this template but save a copy of this template
user directories.
C:\ProgramData\Siemens\MotionControl\
C:\ProgramData\Siemens\MotionControl\
C:\ProgramData\Siemens\MotionControl\
See also: Directory structure and file conventions (Page 11).
How the configuration file works
You can configure the key filter in section
sign (#) are comments as to which line further down deactivates a particular keystroke.
● To activate a particular keystroke first find the key it is in the comment and then set the
value 0 next to it.
● To allow all keystrokes and thus deactivate the key filter (factory setting), set the value 0
next to key
If value 0 is set for this key, all other keys will be ignored and the key filter is deactivated.
Table 4- 1
Overview: Key filter in the configuration file pcuhwsvc.ini
Section
Key
Value
Factory setting
pcuhwsvc.ini (Vorlage im Verzeichnis ...\siemens\System\etc)
//startup diagnostic entries
[SERVER]
FTP=hmisvr PCU betaftpd
DHCP=hmisvr PCU udhcpd
TFTP=hmisvr PCU netkit-tftpd
TCUHWS=hmisvr TCU hardware services
VNC=uvnc service
[APPLICATION]
[KEYB FILTER]
# -------------------------------------------
# SIEMENS KEYBOARD-FILTER DRIVER SECTION
# -------------------------------------------
# Filtering Key Sequences
# =======================
# Activation of Key-Sequences to be ignored
# SeqAct x
# The following 20 sequences are implemented
46
C:\ProgramData\Siemens\MotionControl\Siemens\System\etc\
KeySequencesEnable
user
\System\etc\
addon
\System\etc\
oem
\System\etc\
. The lines identified by a number
[KEYB_FILTER]
.
[KEYB_FILTER]
SeqActive_x
0 = specific keystroke activated
1 = specific keystroke will be filtered and is deactivated
1
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
in one of the
pcuhwsvc.ini
PCU Base Software (IM10)

Advertisement

Table of Contents
loading