Table 5- 2
IP settings in the "Network settings" dialog box
Section
Adapter configuration
Host configuration
PCU Base Software (IM10)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Settings
Adapter
DHCP Enabled
Address
Subnet
Default Gateway
Name Server
Suffix Search List
Backing up and restoring data
5.4 Network settings in the Service Center
Purpose
Select the Ethernet interface that you want
to configure.
All settings in Section "Adapter
configuration" refer to the selected Ethernet
interface.
Select whether the addresses are to be
fetched dynamically from the DHCP server.
If the check box is deactivated, you must
make the settings manually.
Set the IP address of the NCU
You can specify an IP address from the
following range:
192.168.214.250 - 254
Enter a subnet mask, e.g. 255.255.255.0
Set the IP address of the standard gateway.
A standard gateway creates a standard
route in the IP routing table for all
destinations that are not in the subnetwork.
Set the IP address of the name server.
A name server answers questions asked
about a domain name zone using a DNS
database.
Parameterize a search list for DNS suffix,
e.g. "network.com."
The factory setting of the Ethernet interface
"Local Area Connection" is ".local."