Configuring The Pcu Installer - Siemens SINUMERIK 840D sl Commissioning Manual

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Installing and configuring updates and automation software
4.8 PCU Installer
4.8.3

Configuring the PCU Installer

You can define PCU Installer operation in the associated configuration file.
For example, you can configure the following here:
● Which directories have been checked how many times for new setup packages.
● That installations are not been started automatically while certain software is active.
Procedure
To configure the PCU Installer, proceed as follows:
1. Switch to the template directory:
C:\ProgramData\Siemens\MotionControl\siemens\System\etc\
The settings can be viewed in the template
2. Save a copy of the template
3. In the new file (e.g.
section names and keys that are to differ from the template.
in the
4. Adapt the values of the keys. You will find information about the syntax and setting
options in the reference or in the comments of the configuration file.
5. Save your file.
52
C:\ProgramData\Siemens\MotionControl\user\System\etc\
C:\ProgramData\Siemens\MotionControl\addon\System\etc\
C:\ProgramData\Siemens\MotionControl\oem\System\etc\
...\addon\System\etc\PCUInst.ini
All key pairs that do not exist in your file are automatically transferred from the template
directory.
Siemens
See also: Directory structure and file conventions (Page 11).
PCUInst.ini
to one of the user directories:
PCUInst.ini
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
.
), delete all data except those
PCU Base Software (IM10)