Siemens SINUMERIK 840D sl Commissioning Manual page 1029

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Table 3- 3
Settings
SYSTEM
AUTO_OP_1
AUTO_OP_2
AUTO_MON_1
PCU Base Software (IM10)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Settings in the configuration file
Meaning
The resolution is not specially set; i.e., the resolution last used in the
system is active, e.g., the resolution which had been set manually in the
Control Panel.
Default:
During boot up, the resolution is automatically set ("PCU panel" has priority)
in accordance with the following scenarios:
Example 1: There is a PCU panel (irrespective of whether there is a PCU monitor and
TCU panels)
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is set to the max. resolution of the PCU panel
(max. 1280x1024).
Example 2: There is no PCU panel, however there is a PCU monitor (irrespective of
whether there are any TCU panels):
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is not specially set; i.e., the resolution last used in the
system is active, e.g., the resolution which had been set manually in the
Control Panel.
(Different to AUTO_OP_2 !)
Like AUTO_OP_1, except:
Example 2: There is no PCU panel, however there is a PCU monitor
(irrespective of whether there are any TCU panels):
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is set to the max. resolution of the PCU monitor, reduced to
the next lowest SINUMERIK resolution. The SINUMERIK resolutions are
640x480, 800x600, 1024x768 and 1280x1024.
Example: In the case of a PCU monitor with a max. resolution of 1440x900,
the SINUMERIK resolution setting is 1280x1024.
During boot up, the resolution is automatically set ("PCU monitor" has
priority) in accordance with the following scenarios:
Example 1: There is a PCU monitor (irrespective of whether there is a PCU panel and
TCU panels)
[in active TCU mode:
The following additional condition applies: PCU is activated (with dynamic
resolution switching enabled)]:
The resolution is set to the max. resolution of the PCU monitor, reduced to
the next lowest SINUMERIK resolution. The SINUMERIK resolutions are
640x480, 800x600, 1024x768 and 1280x1024.
Example: In the case of a PCU monitor with a max. resolution of 1440x900,
the SINUMERIK resolution setting is 1280x1024.
If there is a PCU panel, the display there is panned if the max. resolution of
the PCU panel is lower than the max. resolution of the PCU monitor.
3.8 Set the resolution in the tcu.ini
tcu.ini
Configuration of the system
27