4.8.2

Activate PCU Installer

In the delivery condition of the PCU 50.5, the PCU Installer is deactivated.
If you complete installation of the PCU Base Software with Windows 7 attended, or have not
configured activation of the PCU Installer in the answer file, you must activate the PCU
Installer manually as described below.
Further information
If you complete installation of the PCU-Basesoftware unattended, you can have the PCU
Installer activated via the
(Page 17).
Precondition
● The PCU Installer is deactivated
● The PCU is switched on and the Service Desktop is active
Procedure
To activate the PCU Installer, proceed as follows:
1. Call the prompt.
2. Enter the following command at the prompt and confirm the entry:
3. Log off or restart the PCU 50.5.
Result
The PCU Installer was been activated and checks the setup directories during startup of the
PCU 50.5.
The following changes have been made to the configuration file
C:\ProgramData\Siemens\MotionControl\user\System\etc\
In section
To use the PCU Installer during operation of the PCU 50.5, too, you must make an additional
setting in the Configuration File (Page 52):
[processing_systemphase]
StartState=Activated
PCU Base Software (IM10)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
unattend.xml
C:\Program Files
(x86)\Siemens\MotionControl\Siemens\System\etc\write_ini_entry.exe"
"C:\ProgramData\Siemens\MotionControl\user\System\etc\PCUInst.ini"
processing_loginphase StartState activated
[processing_loginphase]
Installing and configuring updates and automation software
answer file. See Configuring an answer file
, the setting
StartState=activated
4.8 PCU Installer
in directory
PCUInst.ini
:
has been made.