Prerequisites
After IPSec authentication is enabled in a RIPng process or on a RIPng interface, the
configuration takes effect immediately. There is no need to restart the RIPng process.
Procedure
l
l
----End
Example
Run the display ripng interface command, and you can view the name of an SA used in IPSec
authentication on a RIPng interface.
<Router > display ripng 1 interface GigabitEthernet1/0/0 verbose
GigabitEthernet1/0/0
Run the display ripng statistics interface command, and you can view the number of RIPng
packets that failed authentication.
<Router > display ripng 1 statistics interface gigabitethernet 1/0/0
GigabitEthernet1/0/0(FE80::2E0:64FF:FE10:8142)
Statistical information

------------------------------------------------------------------

Periodic updates sent
Triggered updates sent
Response packet sent
Response packet received
Response packet ignored
Request packet sent
Request packet received
Request packet ignored
Bad packets received
Routes received
Routes sent
Bad routes received
Packet send failed
Packet IPSEC6 Auth failed

4.10 Configuration Examples

In actual networking, different RIPng features have different applications.
Issue 02 (2014-09-30)
Run the display ripng process-id interface [ interface-type interface-number ]
[ verbose ] command to check the SA used in IPSec authentication.
Run the display ripng process-id statistics interface { all | interface-type interface-
number [ verbose | neighbor neighbor-ipv6-address ] } command to check the number of
RIPng packets that failed authentication.
FE80::A0A:200:1
State : UP, Protocol : RIPNG, MTU : 1440
Metricin
: 0
Metricout
: 1
Default Route : Disabled
Poison Reverse : Disabled
Split Horizon : Enabled
Authentication : IPSEC (SA - sa1)
NOTE
Examples in this document use interface numbers and link types of the NE40E-X8. In real world situations,
the interface numbers and link types may be different from those used in this document.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Last min
Last 5 min
5
23
5
30
10
34
15
38
0
0
1
3
4
20
0
0
0
0
0
0
0
0
0
0
0
0
0
0
4 RIPng Configuration
Total
259
408
434
467
0
8
40
0
0
0
0
0
0
2
253

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Quidway netengine40eNe40eNe80e