3.
4.
Step 4 Enable static BFD on an interface.
1.
2.
3.
----End
Checking the Configurations
After configuring static BFD for RIP, run the display rip process-id command to check BFD
for RIP configurations on the specified interface. interface [ interface-type interface-number ]
verbose
Run the display rip process-id interface interface-type interface-number verbosecommand.
The command output shows that static BFD has been enabled on GigabitEthernet1/0/0. For
example:
<HUAWEI> display rip 1 interface gigabitethernet1/0/0 verbose
GigabitEthernet1/0/0 (172.16.1.1)
State
Metricin : 0
Metricout : 1
Input
Protocol : RIPv1 Compatible (Non-Standard)
Issue 02 (2014-09-30)
The local discriminator is set.
l Run:
discriminator remote discr-value
The remote discriminator is set.
The local discriminator must be the remote discriminator of the device on the other end;
otherwise, a BFD session cannot be established. The local and remote discriminators cannot
be modified after being configured.
NOTE
local discr-value set on the local device is the same as that of remote discr-value set on the remote
device.remote discr-value set on the local device is the same as that of local discr-value set on the
remote device.
Run:
commit
The configuration is committed.
Run:
quit
Return to the system view.
Run:
interface interface-type interface-number
The view of the specified interface is displayed.
Run:
rip bfd static
Static BFD is enabled on the interface.
Run:
quit
Return to the system view.
: UP
MTU : 500
: Enabled
Output
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
: Enabled