Comtech EF Data CDM-570A Installation And Operation Manual page 326

70/140 mhz/l-band/reduced chassis depth/with optional high performance packet processor
Hide thumbs Also See for CDM-570A:
Table of Contents

Advertisement

Command
Parameter
(Instruction
Type
Code and
Qualifier)
BUC Software
N/A
2 bytes
Version
BUC Temperature N/A
3 bytes
Serial-based Remote Product Management
Arguments for
Command or
Response to
Query
Query only.
Returns the BUC software version in the form xx.
When unavailable, response is 00
Note: Command valid only when the FSK and BUC power are turned On.
Example: <0/BSV?
>0/BSV=05 (Software version 05)
Query only.
Returns BUC temperature is returned, in the form sxx, where:
s = sign (+ or –)
xx = value
When unavailable, response is –99
Note: This query is valid only when the FSK and BUC power are turned On.
Example: <0/BUT?
>0/BUT=–13 (BUC temperature is –13 degrees C)
CDM-570A/570AL Satellite Modem with Optional Packet Processor
Description of Arguments
8–60
Revision 5
Query
Response to
(Instruction Code
Command
and Qualifier)
N/A
BSV?
BSV=xx
(see Description of
Arguments)
N/A
BUT?
BUT=sxx
(see Description of
Arguments)
MN-CDM570A
Response to
Query

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-570alCdmr-570al

Table of Contents