Comtech EF Data CDM-570A Installation And Operation Manual page 296

70/140 mhz/l-band/reduced chassis depth/with optional high performance packet processor
Hide thumbs Also See for CDM-570A:
Table of Contents

Advertisement

Command
Parameter
(Instruction
Type
Code and
Qualifier)
Retrieve Next 5
unread stored
Statistics
(continued)
1:1 Operational
ASW=
1 byte,
Mode
value of 0 or 1
Force 1:1 Switch
FSW=
None
Serial-based Remote Product Management
Arguments for
Command or
Response to
Query
For IP-ACM mode:
{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Subbody{CR}Sub-body
where Sub-body = AA.ABB.BC,DE,Fddmmyyhhmmss:
AA.A=Minimum Eb/No during sample period.
BB.B=Average Eb/No during sample period.
C=IP-ACM Rx ModCod that was current at time the statistic entry was logged.
D=Maximum Rx ModCod in hex during sample period.
E=Minimum Rx ModCod in hex during sample period.
ddmmyyhhmmss = date/time stamp.
Notes:
1) If there are no new events, the unit response is RNS*.
2) If less than 5 statistics are to be retrieved, the remaining positions are padded
with zeros.
3) If you change your operating mode between non-IP-ACM and IP-ACM modes,
Comtech EF Data recommends that you execute the Clear All stored Statistics
(CAS=) command before retrieving any further statistics.
Command or Query.
Sets or returns 1:1 operational mode in the form x, where
0 = Unit is in Manual Mode
1 = Unit is in Auto Mode
Note: In Manual Mode, all fault relays are forced to the non-faulted condition. This
allows the online unit to be configured without an unintended switchover to the
backup unit.
Command only.
This command takes no arguments.
Forces the unit to toggle the Unit Fail relay to the 'fail' state for approximately
500ms. If the unit is part of a 1:1 pair and it is currently the 'On Line' unit, this
forces a switchover, so the unit is then be in 'Standby' mode.
Notes:
1) The 1:1 redundancy system must be installed.
2) Both online and offline units must be in Manual Mode for this command to
function.
3) If the 1:1 redundancy system is not installed, then the command returns FSW?
4) If the unit is offline, then the command will return FSW?
CDM-570A/570AL Satellite Modem with Optional Packet Processor
Description of Arguments
8–30
Revision 5
Query
Response to
(Instruction Code
Command
and Qualifier)
ASW=
ASW?
ASW=x
ASW?
(see Description of
ASW*
Arguments)
ASW#
FSW= (message
N/A
N/A
OK)
MN-CDM570A
Response to
Query

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-570alCdmr-570al

Table of Contents