Command
Parameter
(Instruction
Type
Code and
Qualifier)
Tx BERT
TBP=
1 byte
Pattern
Rx BERT
RBP=
1 byte
Pattern
BERT Error Insert BKE=
1 byte, value of
0 or 1
BERT Restart
BRM=
None
Monitor
BERT Result
N/A
8 bytes
in bit errors
Serial-based Remote Product Management
Arguments for
Command or
Response to
Query
Command or Query.
Valid only in CDM-570A Compatible Mode (CMO=1).
Sets or returns Tx BERT Pattern, in the form x, where:
0=1:1
1=2047
2=2^15-1
3=2^23-1
Example: <0/TBP=1 (Tx BERT Pattern is 2047)
Command or Query.
Valid only in CDM-570A Compatible Mode (CMO=1).
Sets or returns Rx BERT Pattern, in the form x, where:
0=1:1
1=2047
2=2^15-1
3=2^23-1
Example: <0/RBP=1 (Rx BERT Pattern is 2047)
Command only.
Valid only in CDM-570A Compatible Mode (CMO=1).
Inserts 1 error in the form x, where:
x=1
Example: <0/BKE=1
Command only.
Valid only in CDM-570A Compatible Mode (CMO=1).
This command takes no arguments.
Restarts the BERT Monitor.
Example: <0/BRM=
Query only.
Valid only in CDM-570A Compatible Mode (CMO=1).
Returns BERT monitor results in bit errors, in the form x.xxE+yy
Example: <0/BRE?
>0/BRE=8.70E+05
CDM-570A/570AL Satellite Modem with Optional Packet Processor
Description of Arguments
8–35
Revision 5
Query
Response to
(Instruction Code
Command
and Qualifier)
TBP=
TBP?
TBP=x
TBP?
(see Description of
TBP#
Arguments)
RBP=
RBP?
RBP=x
RBP?
(see Description of
RBP#
Arguments)
BKE=
N/A
BKE=x
BKE?
(see Description of
BKE#
Arguments)
BRM=
N/A
N/A
N/A
BRE?