Config: Alarm Mask) Ref; Config: Alarm Mask) Buc (Cdm/R-570Al L-Band Units Only); Config: Alarm Mask) Lnb (Cdm/R-570Al L-Band Units Only) - Comtech EF Data CDM-570A Installation And Operation Manual

70/140 mhz/l-band/reduced chassis depth/with optional high performance packet processor
Hide thumbs Also See for CDM-570A:
Table of Contents

Advertisement

6.3.2.9.3

(CONFIG: Alarm Mask) Ref

Reference Alarm:
Masked (◄ ►,ENT)
Active
◄ ►
Use the
arrow keys to select Active or Masked. Press ENTER.
When you select Active, the modem generates a Transmit Traffic fault whenever it sees that:
External Reference is selected, and
There is no signal activity at the External Reference port.
When you select Masked, the modem generates no alarm.
6.3.2.9.4

(CONFIG: Alarm Mask) BUC (CDM/R-570AL L-Band Units ONLY)

See Chapter 10. CDM-570A/570AL ODU (TRANSCEIVER, BUC, LNB) M&C
OPERATIONS for complete details about using this modem-specific menu
branch.
BUC Alarm:
Active
Masked (◄ ►,ENT)
◄ ►
Use the
arrow keys to set the alarm as Active or Masked for the BUC, if connected.
6.3.2.9.5

(CONFIG: Alarm Mask) LNB (CDM/R-570AL L-Band Units ONLY)

See Chapter 10. CDM-570A/570AL ODU (TRANSCEIVER, BUC, LNB) M&C
OPERATIONS for complete details about using this modem-specific menu
branch.
LNB Alarm:
Active
Masked (◄ ►,ENT)
◄ ►
Use the
arrow keys to set the alarm as Active or Masked for the LNB, if connected.
Front Panel Operation
CDM-570A/570AL Satellite Modem with Optional Packet Processor
6–44
Revision 5
MN-CDM570A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdm-570alCdmr-570al

Table of Contents