Rmon Alarm - Cisco Nexus 7000 Series Reference Manual

Nx-os system management command reference
Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

rmon alarm

rmon alarm
To configure a 32-bit remote monitoring RMON alarm, use the rmon alarm command. To delete RMON
alarms, use the no form of this command.
Syntax Description
alarm number
mib-object
sample-interval
absolute
delta
rising-threshold
value
rising-event
falling-threshold
value
falling-event
owner alarm
owner
Defaults
None
Command Modes
Global configuration mode
Supported User Roles
network-admin
vdc-admin
Command History
Release
4.0(1)
Usage Guidelines
This command does not require a license.
Cisco Nexus 7000 Series NX-OS System Management Command Reference
354
rmon alarm alarm number mib-object sample-interval {absolute | delta} rising-threshold value
[rising-event] falling-threshold value [falling-event] [owner alarm-owner]
no rmon alarm alarm-number
RMON alarm number. The range is from 1 to 65535.
MIB object to monitor. The maximum length is 80 characters.
Sample interval in seconds. The range is from 1 to 2147483647.
Specifies to test each sample directly.
Specifies to test the difference (delta) between the current and previous sample.
Specifies the rising threshold value. The range is from 2147483648 to 2147483647.
(Optional) Event to trigger on a rising threshold crossing. The range is from 1 to
65535. If no event is specified, event 0 is used.
Specifies the falling threshold value. The range is from 2147483648 to
2147483647.
(Optional) Event to trigger on a falling threshold crossing. The range is from 1 to
65535. If no event is specified, event 0 is used.
(Optional) Specifies an owner for the alarm. The maximum size is 80 characters.
Modification
This command was introduced.
R Commands
OL-25806-03

Advertisement

Table of Contents
loading

Table of Contents