Cisco Nexus 7000 Series Reference Manual page 430

Nx-os system management command reference
Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

source exception
source exception
To configure the source as an exception Ethernet Switched Port Analyzer (SPAN) or Encapsulated
Remote Switched Port Analyzer (ERSPAN) session, use the source exception command. To remove the
source as an exception SPAN or ERSPAN session, use the no form of this command.
Syntax Description
layer3
fabricpath
other
all
Defaults
None
Command Modes
config-monitor mode (for a SPAN session)
config-erspan-src mode (for an ERSPAN session)
Supported User Roles
network-admin
vdc-admin
Command History
Release
6.2(2)
Usage Guidelines
M1 and M2 Series modules support exception SPAN only in the nonadministration virtual device context
(VDC), and at least one interface of the module must be present for the VDC.
This command does not require a license.
Examples
This example shows how to configure the source as an exception SPAN session:
switch(config)# monitor session 1
switch(config-monitor)# source exception all
This example shows how to configure the source as an exception ERSPAN session:
switch(config)# monitor session 3 type erspan-source
switch(config-erspan-src)# source exception all
Cisco Nexus 7000 Series NX-OS System Management Command Reference
402
source exception {layer3 | fabricpath | other | all}
no source exception {layer3 | fabricpath | other | all}
Specifies the Layer 3 exception type for F2 Series and M Series modules.
Specifies the FabricPath exception type for F Series modules.
Specifies exceptions for M Series modules that are dropped through redirect
registers programmed with a drop destination interface.
Includes all Layer 3, FabricPath, and other exceptions.
Modification
This command was introduced.
S Commands
OL-25806-03

Advertisement

Table of Contents
loading

Table of Contents