Ethanalyzer Local Interface - Cisco Nexus 7000 Series Reference Manual

Nx-os system management command reference
Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

E Commands

ethanalyzer local interface

To capture packets to or from the supervisor or management interface, use the ethanalyzer local
interface command. To stop packet capture, use the no form of this command.
Syntax Description
inband
mgmt
capture-filter
capt-expression
capture-ring-buffer
duration
seconds
write
files
files
bootflash
filesize
kilobytes
display-filter
disp-expression
limit-captured-frames
limit
limit-frame-size bytes
write location
brief
Defaults
No packets captured.
OL-25806-03
ethanalyzer local interface {inband | mgmt} [[capture-filter capt-expression]
[capture-ring-buffer duration seconds write bootflash | files files write bootflash |
filesize kilobytes write bootflash [display-filter disp-expression] [limit-captured-frames limit]
[limit-frame-size bytes] [write location]] [brief]
no ethanalyzer local interface {inband | mgmt} [[capture-filter capt-expression]
[capture-ring-buffer duration seconds write bootflash | files files write bootflash | filesize
kilobytes write bootflash [display-filter disp-expression] [limit-captured-frames limit]
[limit-frame-size bytes] [write location]] [brief]
Captures packets going between the supervisor module and the interface
modules.
Captures packets going to or from the mgmt0 port.
(Optional) Filters the display of output based on the expression. The
expression is a quoted string.
(Optional) Captures ring buffer option.
Stop writing to the file or switch to the next file after value seconds have
elapsed.
Duration in seconds. The range is from 0-2147483647.
Filename to save capture to.
Stop writing to capture files after value number of files were written or begin
again with the first file after value number of files were written (form a ring
buffer).
Number of files. The range is from 2 to 64.
Specifies the bootflash file name.
Stop writing to a capture file or switch to the next file after it reaches a size
of value kilobytes.
Size in kilobytes. The range is from 1to 65536.
(Optional) Filters the display of output based on the expression. The
expression is a quoted string.
(Optional) Configures the maximum number of frames to capture. The range
is from 0 to 2147483647. The default is 100.
(Optional) Captures the configured number of bytes from a frame. The range
is from 64 to 65535.
(Optional) Saves the captured information to the configured location. The
location can be any case-sensitive, alphanumeric string up to 64 characters.
(Optional) Displays the protocol summary of the captured packets.
Cisco Nexus 7000 Series NX-OS System Management Command Reference
ethanalyzer local interface
139

Advertisement

Table of Contents
loading

Table of Contents