Cisco Nexus 7000 Series Reference Manual page 504

Nx-os system management command reference
Hide thumbs Also See for Nexus 7000 Series:
Table of Contents

Advertisement

show event manager system-policy
Examples
This example shows how to display the EEM system policies:
switch# show event manager system-policy
Name : __BootupPortLoopback
ailure of GOLD "BootupPortLoopback" test
ted ports after 10 consecutive failures of GOLD "PortLoopback" test
ted ports after 10 consecutive failures of GOLD "RewriteEngineLoopback" test
ASIC device/instance after 20 consecutive failures of GOLD
test
consecutive failures of GOLD "CompactFlash" test
ils
Disable the port
consecutive failures of GOLD "ExternalCompactFlash" test
switch#
Cisco Nexus 7000 Series NX-OS System Management Command Reference
476
Description : Do CallHome, log error on affected ports after 1 consecutive f
Overridable : Yes
Name : __PortLoopback
Description : Do CallHome, log error and disable further HM testing on affec
Overridable : Yes
Name : __RewriteEngineLoopback
Description : Do CallHome, log error and disable further HM testing on affec
Overridable : Yes
Name : __asic_register_check
Description : Do CallHome, log error and disable further HM testing for that
Overridable : Yes
Name : __compact_flash
Description : Do CallHome, log error and disable further HM testing after 20
Overridable : Yes
Name : __crypto_device
Description : Do CallHome and log error when GOLD "CryptoDevice" test fails
Overridable : Yes
Name : __eobc_port_loopback
Description : Do CallHome and log error when GOLD "EOBCPortLoopback" test fa
Overridable : Yes
Name : __ethpm_debug_1
Description : Action: none
Overridable : Yes
Name : __ethpm_debug_2
Description : Action: none
Overridable : Yes
Name : __ethpm_debug_3
Description : Action: none
Overridable : Yes
Name : __ethpm_debug_4
Description : Action: none
Overridable : Yes
Name : __ethpm_link_flap
Description : More than 30 link flaps in 420 seconds interval. Action: Error
Overridable : Yes
Name : __external_compact_flash
Description : Do CallHome, log error and disable further HM testing after 20
Overridable : Yes
Show Commands
"AsicRegisterCheck"
OL-25806-03