Rmon Alarm - Cisco AJ732A - MDS 9134 Fabric Switch Command Reference Manual

Cisco mds 9000 family command reference guide - release 4.x (ol-18089-01, february 2009)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 20
R Commands
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

rmon alarm

To configure a 32- bit remote monitoring (RMON) alarm, use the rmon alarm command in
configuration mode. To delete an RMON alarm, use the no form of the command.
Syntax Description
alarm-number
mib-object
sample-interval
absolute
delta
rising-threshold value
rising-event
falling-threshold value Specifies the falling threshold value. The range is –2147483648 to
falling-event
owner alarm-owner
Defaults
Disabled.
Command Modes
Configuration mode.
Command History
Release
2.0(x)
Usage Guidelines
Use the rmon event command to configure the events for alarms.
The maximum number of RMON alarms currently is only configurable through the device manager and
threshold manager GUI. A CLI command is not available to change this maximum value.
We recommand setting alarm sample intervals to 30 seconds or higher to prevent excessive load on the
Note
system.
OL-18089-01, Cisco MDS NX-OS Release 4.x
rmon alarm alarm-number mib-object sample-interval {absolute | delta} rising-threshold value
[rising-event] falling-threshold value [falling-event] [owner alarm-owner]
no rmon alarm alarm-number
Specifies the RMON alarm number. The range is 1 to 65535.
Specifies the MIB object to monitor. Maximum length is 80 characters.
Note
Specifies the sample interval in seconds. The range is 1 to 2147483647.
Tests each sample directly.
Tests the difference (delta) between the current and previous sample.
Specifies the rising threshold value. The range is –2147483648 to
2147483647.
(Optional) Specifies the event to trigger on rising threshold crossing. The
range is 1 to 65535. If no event is specified, event 0 is used.
2147483647.
(Optional) Specifies the event to trigger on rising threshold crossing. The
range is 1 to 65535. If no event is specified, event 0 is used.
(Optional) Specifies an owner for the alarm. Maximum size is 80 characters.
Modification
This command was introduced.
The MIB object identifier must be fully numbered, dotted-decimal
notation, not the text string description.
Cisco MDS 9000 Family Command Reference
rmon alarm
20-25

Advertisement

Table of Contents
loading

Table of Contents