event module-failure

event module-failure
To specify an event criteria for an Embedded Event Manager (EEM) applet that is run on the basis of a
module failure event, use the event module-failure command. To remove the module failure event
criteria, use the no form of this command.
Syntax Description
type err-name
module
module
all
count count
time interval
Cisco Nexus 7000 Series NX-OS System Management Command Reference
156
event module-failure type err-name module {all | module} count count [time interval]
no event module-failure type err-name module {all | module} count count
Specifies the type of failure condition. Select one of the err-name conditions:
any—Any failure
addon-sequence-failure—Addon sequence failure
hitless-upgrade-diag-failure—Runtime diagnostic failure after hitless upgrade
hitless-upgrade-failure—Hitless upgrade failure
hitless-upgrade-procmgr-notif—LC software failure after hitless upgrade
hitless-upgrade-reg-failure—Registration failure after hitless upgrade
hitless-upgrade-seq-timeout—Hitless upgrade sequence timeout
image-download-failed—Image download failure
image-upgrade-failed—Image upgrade failed
insertion-seq-failure—Insertion sequence failure
lc-failed—LC failed
lc-not-responding—LC not responding
lc-ready-timeout—LC ready timeout
lc-sw-failure—LC software failure
registration-failure—Registration failure
registration-timeout—Registration timeout
runtime-diag-failure—Runtime diag failure
runtime-diag-timeout—Runtime diag timeout
sequence-timeout—Sequence timeout
srg-info-resp-timeout—SRG info response timeout
unexpected-registration—Unexpected registration received
upgrade-srg-not-compatible—Upgrade SRG not compatible
Specifies that one module or all modules must be monitored.
Number of a specific module to be monitored.
Specifies that all modules are to be monitored.
Specifies the number of matching occurrences before a module failure event is
triggered. The range is from 0 to 4294967295.
(Optional) Specifies the time interval (in seconds) within which the events need
to happen. The range is from 0 to 4294967295.