Link - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no power [{L1|L2}}
The parameters have the following meaning:
Parameters
L1
L2
If you do not select any parameters from the parameter list, the default value "L1 and L2" is
used.
Result
The setting for monitoring the power supplies is configured.
Further notes
You can display the current setting with the
You enable the function with the
12.1.14.12

link

Description
With this command, you configure and enable the monitoring of the physical network
connections for cable breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
link {up|down}[{<ifXtype><iface_list>}]
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
No monitoring of power supply 1
No monitoring of power supply 2
show events faults config
command.
power
The parameters have the following meaning:
Diagnostics
12.1 Event and fault handling
command.
563

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents