Sender Mail-Address - Siemens SCALANCE XM-400 Configuration Manual

Simatic net industrial ethernet switches command line interface
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Network protocols
7.5 SMTP client
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no smtp-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>}
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN(100)
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 30)".
Result
The SMTP server entry is deleted.
Further notes
You configure an SMTP server entry with the
7.5.4.3

sender mail-address

Description
With this command, you configure the e-mail name of the sender.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
298
Description
Keyword for an IP address
Value for an IPv4 unicast address
Keyword for a domain name
Domain name (Fully Qualified
Domain Name)
smtp-server
Range of values
-
Enter a valid IPv4 unicast address.
-
Maximum of 100 characters
command.
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07