12.2.2.1

syslogserver

Description
With this command, you configure the Syslog server.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
syslogserver {ipv4 address}[port]{info | warning | critical}
The parameters have the following meaning:
Parameter
ipv4 address
port
info
warning
critical
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 30)".
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for the Syslog server are configured. The Syslog server was entered in the table
Further notes
You delete the entry with the
You can display the status of this function and other information with the
config
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
Description
IP v4 address
Port of the Syslog server on which the messages are
received
Information
Warning
Critical
command.
command.
no syslogserver
Diagnostics
12.2 Syslog client
Range of values
Enter a valid IPv4 address
0 ... 65535
Default: 514
-
-
-
show events