Functions specific to SCALANCE
4.3 Panel button
4.3
Panel button
This section describes the commands relevant for working with the Panel Button function.
4.3.1
Commands in the global configuration mode
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
4.3.1.1
set panel-button control-factory-defaults
Description
With this command, you enable or disable the following function of the "SELECT/SET"
button:
● When display mode "1" "port status" is displayed, and the button is pressed for more than
12 seconds, there is a restart with the factory settings.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
set panel-button control-factory-defaults{enable|disable}
The parameters have the following meaning:
Parameter
enable
disable
112
configure terminal
end
Description
Enables the function for restarting with factory settings
Default: enabled
Disables the function for restarting with factory settings
SCALANCE XM-400/XR-500 Command Line Interface
Configuration Manual, 05/2014, C79000-G8976-C252-07
command to change to this mode.
or
command and are then in the
exit