Diagnostics
12.1 Event and fault handling
Result
The setting deciding which messages of the device are not stored or forwarded is
configured.
Further notes
You display the status of the events and the clients with the
You configure which of the various message types of the device will be stored or forwarded
with the
12.1.14.6

eventgroup

Description
With this command, you configure the message level for alarm message groups.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli (config-events)#
Syntax
Call up the command with the following parameters:
eventgroup <string> {info | warning | critical }
The parameters have the following meaning:
Parameter
string
info
warning
critical
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings of the event grouping are configured.
558
command.
event config
Description
Name of the event group
Message level information
Message level warning
Message level critical
show events config
Range of values / note
max. 32 characters
-
-
-
SCALANCE XM-400/XR-500 Command Line Interface