Siemens SCALANCE XB-200 Configuration Manual

Siemens SCALANCE XB-200 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XB-200:
Table of Contents

Advertisement

SCALANCE XB-200/XC-200/XP-200
Web Based Management
SIMATIC NET
Industrial Ethernet switches
SCALANCE XB-200/XC-200/XP-
200 Web Based Management
Configuration Manual
07/2016
C79000-G8976-C360-04
___________________
Introduction
___________________
Description
___________________
Assignment of an IP address
___________________
Technical basics
___________________
Configuring with Web Based
Management
___________________
Troubleshooting/FAQ
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SCALANCE XB-200

  • Page 1 ___________________ SCALANCE XB-200/XC-200/XP-200 Introduction Web Based Management ___________________ Description ___________________ SIMATIC NET Assignment of an IP address ___________________ Technical basics Industrial Ethernet switches SCALANCE XB-200/XC-200/XP- ___________________ Configuring with Web Based 200 Web Based Management Management ___________________ Troubleshooting/FAQ Configuration Manual 07/2016...
  • Page 2: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Login ............................41 The "Information" menu ......................44 5.3.1 Start page ..........................44 5.3.2 Versions ..........................50 5.3.3 I&M ............................51 5.3.4 ARP table ..........................52 5.3.5 Log Table ..........................53 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 4 Users ............................ 124 5.4.10 System Time ........................127 5.4.10.1 Manual Setting ........................127 5.4.10.2 DST Overview ........................129 5.4.10.3 DST Configuration ....................... 131 5.4.10.4 SNTP Client ......................... 134 5.4.10.5 NTP Client ..........................137 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 5 MST General ......................... 204 5.5.8.5 MST Port ..........................205 5.5.8.6 Enhanced Passive Listening Compatibility ................208 5.5.9 Loop detection ........................209 5.5.10 Link aggregation ........................211 5.5.11 DCP forwarding ........................214 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 6 802.1x Authenticator ......................254 5.7.5 Management ACL ........................ 258 Troubleshooting/FAQ ........................... 263 Downloading new firmware using TFTP without WBM and CLI .......... 263 Message: SINEMA configuration not yet accepted ............. 265 Index ..............................267 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 7: Introduction

    All other properties are identical. This Configuration Manual applies to the following software versions: ● SCALANCE XB-200 firmware as of version 2.0 ● SCALANCE XC-200 firmware as of version 2.1 ● SCALANCE XP-200 firmware as of version 2.0...
  • Page 8 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support under the following entry IDs: – 27069465 (http://support.automation.siemens.com/WW/view/en/27069465) Industrial Ethernet / PROFINET Industrial Ethernet System Manual –...
  • Page 9 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 10 Siemens AG: SIMATIC NET, SCALANCE, C-PLUG, OLM Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 11: Description

    ✓ ✓ ✓ PROFINET ✓ ✓ ✓ EtherNet/IP ✓ ✓ ✓ Power over Ethernet ✓ ("PoE" identifier in device names) Cable tester ✓ ✓ ✓ SFP diagnostics ✓ Fiber monitoring ✓ SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 12 ✓ ✓ ✓ Security Passwords ✓ ✓ ✓ RADIUS authentication ✓ ✓ ✓ MAC authentication ✓ ✓ Guest VLAN ✓ ✓ 802.1X reauthentication ✓ ✓ ✓ Management ACL ✓ ✓ ✓ SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 13: Product Characteristics

    ● Redundancy method Spanning Tree Protocol. The redundancy mechanism Spanning Tree defines several connection paths between nodes in a network, only one of which is ever active. This suppresses loops and optimizes the paths. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 14: Requirements For Installation And Operation

    A PG/PC with a network connection must be available in order to configure the IE switches. An IP address must be assigned to the IE switch and it must be available in the network, see also "Initial assignment of an IP address (Page 16)". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 15: Assignment Of An Ip Address

    To find out whether two IP addresses belong to the same subnet, the two IP addresses and the subnet mask are ANDed bit by bit. If both logic operations have the save result, both IP addresses belong to the same subnet, for example, 141.120.246.210 and 141.120.252.108. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 16: Initial Assignment Of An Ip Address

    – To be able to assign an IP address to the IE switch with the PST, it must be possible to reach the IE switch via Ethernet. – You will find the PST on the Internet pages of Siemens Industry Online Support under the entry ID 19440762 (http://support.automation.siemens.com/WW/view/en/19440762).
  • Page 17: Address Assignment With Dhcp

    ● CLI via the serial interface For further information on assigning the IP address using the CLI, refer to the documentation "SCALANCE XB-200/XC-200/XP-200 Command Line Interface". ● NCM PC For further information on assigning the IP address using NCM PC, refer to the documentation "Commissioning PC stations - Manual and Quick Start", in the section...
  • Page 18 Assignment of an IP address 3.3 Address assignment with DHCP SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 19: Technical Basics

    Unicast filtering Multicast addresses without active GMRP Multicast addresses with activated GMRP Static MAC addresses in the FDB (Forward Data- base) Layer 3 DHCP Relay Agent interfaces DHCP Relay Agent server SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 20: Profinet

    Management ACLs (access rules for manage- ment) With the SCALANCE XB-200, the number of DHCP pools and manageable IPv4 addresses depends on the number of ports. The number of ports corresponds to the maximum number of DHCP pools and manageable IPv4 addresses.
  • Page 21: Ethernet/Ip

    EDS (Electronic Data Sheet). Electronic Data Sheet Electronic Data Sheet (EDS) is an electronic datasheet for describing devices. The EDS required for EtherNet/IP operation can be found in "System > Load&Save (Page 93)". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 22: Redundancy Mechanism

    New configuration data is not used immediately by a bridge but only after the period specified in the "Forward Delay" parameter. This ensures that operation is only started with the new topology after all the bridges have the required information. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 23: Rstp, Mstp, Cist

    VLANs that the single Rapid Spanning Tree Protocol would globally block. Common and Internal Spanning Tree (CIST) CIST identifies the internal instance used by the switch that is comparable in principle with an internal RSTP instance. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 24: Hrp

    On all other devices in the ring, either the "HRP Client" or "Automatic Redundancy Detection" mode must be activated. ● You configure HRP in Web Based Management, Command Line Interface or using SNMP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 25: Mrp

    ● All other devices in the ring are redundancy clients. Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via a PC with a CP capable of MRP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 26: Configuration In Wbm

    – For all other devices in the ring select "MRP Client" or "Automatic Redundancy Detection". ● You want to use MRP in a ring topology that also includes non-Siemens devices: – For exactly one device in the ring select the role "MRP Auto Manager".
  • Page 27: Configuration In Step 7

    Otherwise, there may be circulating frames that will cause a failure in the network. One device in the ring needs to be configured as "redundancy manager" and all other devices in the ring as "clients". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 28 Note factory settings MRP is disabled and spanning tree enabled for the following brand new IE switches and those set to the factory settings: • SCALANCE XB-200 (Ethernet/IP variants) • SCALANCE XP-200 (Ethernet/IP variants) • SCALANCE XM-400 • SCALANCE XR-500 To load a PROFINET configuration into one of the specified devices, first disable spanning tree on the device.
  • Page 29 Role The choice of role depends on the following use cases. ● You want to use MRP in a topology with one ring only with Siemens devices and without monitoring diagnostic interrupts: Assign all devices to the "mrpdomain-1" domain and the role "Manager (Auto)".
  • Page 30 If you enable this option, existing redundancy settings from WBM, CLI or SNMP, are retained and are not overwritten. The parameters in the "MRP configuration" box are then reset and grayed out. The entries then have no meaning. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 31: Standby

    Ethernet connection to the substitute (slave) Ethernet connection. Standby redundancy Figure 4-2 Example of a redundant link between rings SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 32: Parallel Redundancy Protocol

    VLAN, they are also known as broadcast domains. The particular advantage of VLANs is the reduced network load for the nodes and network segments of other VLANs. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 33: Vlan Tagging

    Ethernet type / length field: Figure 4-3 Structure of the expanded Ethernet frame The additional bytes contain the tag protocol identifier (TPID) and the tag control information (TCI). SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 34 The frame contains only priority information (priority tagged frames) and no valid VLAN identifier. 1- 4094 Valid VLAN identifier, the frame is assigned to a VLAN and can also include priori- ty information. 4095 Reserved SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 35: Snmp

    Note Because the SNMP community strings are used for access protection, do not use the standard values "public" or "private". Change these values following the initial commissioning. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 36 Compared with the previous versions SNMPv1 and SNMPv2c, SNMPv3 introduces an extensive security concept. SNMPv3 supports: ● Fully encrypted user authentication ● Encryption of the entire data traffic ● Access control of the MIB objects at the user/group level SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 37: Quality Of Service

    3. If the second condition is also not met the frames are further processed according to the Trust mode. You configure the Trust mode on the page "QoS Trust (Page 175)". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 38 Technical basics 4.8 Quality of service SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 39: Configuring With Web Based Management

    "Settings" button. Under "Check for newer versions of stored pages:", select "Automatically". ● If a firewall is used, the relevant ports must be opened. – For access using HTTP: TCP port 80 – For access using HTTPS: TCP port 443 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 40 The display on the WBM pages and how you work with them on mobile devices may differ compared with the same pages on desktop devices. Some pages also have an optimized display for mobile devices. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 41: Login

    1. From the drop-down list at the top right, select the language version of the WBM pages. 2. Click the "Go" button to change to the selected language. Note Available languages In this version German and English are available. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 42 You need to repeat the password as confirmation. The password entries must match. Click the "Set Values" button to complete the action and activate the new password. Once you have logged in successfully, the start page appears. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 43 You need to repeat the password as confirmation. The password entries must match. Click the "Set Values" button to complete the action and activate the new password. Once you have logged in successfully, the start page appears. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 44: The "Information" Menu

    The following areas are generally available on every WBM page: ● Selection area (1): Top area ● Display area (2): Top area ● Navigation area (3): Left-hand area ● Content area (4): Middle area SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 45 Configuring with Web Based Management 5.3 The "Information" menu SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 46 ● Logo of Siemens AG When you click on the logo, you arrive at the Internet page of the corresponding basic device in Siemens Industry Online Support. ● Display of: "System Location / System Name" – "System location" contains the location of the device.
  • Page 47 Shows the PROFINET device name. ● Diagnostics Mode Shows whether EtherNet/IP or PROFINET IO is enabled. ● System Name Shows the name of the device. ● Device Type Shows the type designation of the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 48 Click this button to save the configuration data you have entered on the device. Once you have saved, the button becomes inactive again. Note Changing configuration data is possible only with the "admin" role. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 49 "Saving configuration data in progress. Please do not switch off the device". How long saving takes depends on the device. • Do not switch off the device immediately after the timer has elapsed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 50: Versions

    Shows the version of the boot software stored on the device. – Firmware_Running Shows the firmware version currently being used on the device. ● Description Shows the short description of the software. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 51: I&M

    Shows the manufacturer ID. ● Order ID Shows the order number. ● Serial Number Shows the serial number. ● Hardware Revision Shows the hardware version. ● Software version Shows the software version. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 52: Arp Table

    The table has the following columns: ● Interface Shows the interface via which the row entry was learnt. ● MAC Address Shows the MAC address of the destination or source device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 53: Log Table

    "System > Events" menu. This, for example, allows you to record when an authentication attempt failed or when the connection status of a port has changed. The content of the events log table is retained even when the device is turned off. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 54 The number of entries in this table is restricted to 1200. The table can contain 400 entries for each severity. When this number is reached, the oldest entries of the relevant severity are discarded. The table remains permanently in memory. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 55: Faults

    Errors of the "Cold/Warm Start" event can be deleted by a confirmation. The calculation of the time of an error always begins after the last system start. If there are no errors present, the fault LED switches off. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 56: Redundancy

    If the "Clear Fault State" button is enabled, you can delete the fault. 5.3.7 Redundancy 5.3.7.1 Spanning tree Introduction The page shows the current information about the spanning tree and the settings of the root bridge. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 57 ● Regional root address (available only with MSTP) Shows the MAC address of the device. ● Regional Root Cost (available only with MSTP) Shows the path costs from the regional root bridge to the root bridge. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 58 A value between 0 and 240 can be entered for the priority in steps of 16. If you enter a value that cannot be divided by 16, the value is automatically adapted. The default is 128. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 59 Shows the type of the point-to-point link. The following values are possible: – P.t.P. With half duplex, a point-to-point link is assumed. – 
 S hared Media With a full duplex connection, a point-to-point link is not assumed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 60: Ring Redundancy

    – MRP Auto-Manager The IE switch is operating as an MRP manager. Using WBM or CLI the role "MRP Auto-Manager" or using STEP 7 the role "Manager (Auto)" was set. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 61 If the redundancy function is disabled or the device is an "HRP/MRP client" , the text "Redundancy manager disabled" appears. Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counters are reset by a restart. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 62: Standby

    The Standby tab shows the status of the standby function: Description of the displayed values The following boxes are displayed: ● Standby ports Shows the standby port. ● Standby Name Standby Connection Name SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 63 If the standby function is disabled, the text "Standby Disabled" appears in this box. Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counter is reset when there is a restart. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 64: Ethernet Statistics

    ● Out Non Unicast Shows the number of sent frames that are not of the type unicast. ● In Errors Shows the number of all possible RX errors, refer to the tab "Packet Error". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 65: Packet Size

    0.1 is module 0, port 1. Note Display of frame statistics In the statistics relating to frame lengths, note that both incoming and outgoing frames are counted. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 66 For technical reasons, data packets can be indicated on blocked ports. Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counters are reset by a restart. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 67: Packet Type

    "Unicast", "Multicast" and "Broadcast". Description of the button "Reset Counters" button Click "Reset Counters" to reset all counters. The counters are reset by a restart. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 68: Packet Error

    Packets with a length less than 64 bytes. – Oversize Packets discarded because they were too long. – Fragments 
 P ackets with a length less than 64 bytes and a bad CRC checksum. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 69: History

    On the page "Layer 2 > RMON > History", you can set the ports for which samples will be taken. Figure 5-1 History Settings ● Port Select the port for which the history will be displayed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 70 Number of frames with a VLAN tag that have a bad CRC checksum and will be discarded because they are too long. ● Collisions Number of collisions of received frames. ● Utilization [%] Utilization of the port during a sample. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 71: Unicast

    ● VLAN ID Shows the VLAN-ID assigned to this MAC address. ● MAC Address Shows the MAC address of the node that the device has learned or the user has configured. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 72: Multicast

    The entries can be dynamic (the device has learned them) or static (the user has set them). Dependency on the "Base bridge mode" If you change the "Base bridge mode" the existing entries are lost. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 73 Not a member of the multicast group. No multicast frames with the defined multicast MAC address are sent via this port. – F (Forbidden) Not a member of the multicast group. Moreover, on this port may not be learned dynamically with IGMP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 74: Lldp

    An entry remains stored on the device for the time specified here. If the IE switch does not receive any new information from the connected device during this time, the entry is deleted. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 75: Fiber Monitoring Protocol

    You set the values to be monitored on the following page: "Layer 2 > FMP". Description of the displayed values Port Shows the optical ports that support fiber monitoring. This depends on the transceivers. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 76 If no diagnostics information is received from the optical port of the connection partner for 5 cycles, the fiber monitoring connection is assumed to be interrupted. A cycle lasts 5 seconds. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 77: Dhcp Server

    Shows the circuit ID of the DHCP client. ● Allocation Method Shows whether the IPv4 address was assigned statically or dynamically. You configure the static entries in "System > DHCP > Static Leases". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 78 Click this button to go to the previous page. Drop-down list for page change From the drop-down list, select the page you want to go to. "Refresh" button Refreshes the display of the values in the table. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 79: Diagnostics

    No data has been read out yet. "-" is displayed in all boxes. ● Temperature [°C] Shows the current value of the temperature. The display is updated at regular intervals. The value can have a tolerance of +/- 3 °C SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 80: Snmp

    This page displays the created SNMPv3 groups. You configure the SNMPv3 groups in "System" > SNMP".. Description The table has the following columns: ● Group Name Shows the group name. ● User Name Shows the user that is assigned to the group. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 81: Security

    You configure the setting in "System > Configuration". – HTTP/HTTPS: Access to the WBM is possible with HTTP and HTTPS. – HTTPS: Access to the WBM is only possible with HTTPS. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 82 RADIUS query is sent. – RADIUS and fallback local The authentication must be handled via a RADIUS server. A local authentication is performed only when the RADIUS server cannot be reached in the network. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 83: The "System" Menu

    If this function is enabled, you can only access the WBM via HTTPS. ● SMTP Client Enable or disable the SMTP client. You can configure other settings in "System > SMTP Client". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 84 Enable or disable the DHCP client. You can configure other settings in "System > DHCP Client". ● SNMPv1 Traps Enable or disable the sending of SNMPv1 traps (alarm frames). You can configure other settings in "System > SNMP > Traps". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 85 Steps in configuration 1. To use the required function, select the corresponding check box. 2. Select the options you require from the drop-down lists. 3. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 86: General

    A maximum of 255 characters are possible. The system name is also displayed in the CLI input prompt. The number of characters in the CLI input prompt is limited. The system name is truncated after 16 characters. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 87: Coordinates

    The geographic coordinates can also be obtained using a GPS receiver. The geographic coordinates of these devices are normally displayed directly and only need to be entered in the input boxes of this page. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 88 1. Enter the calculated latitude in the "Latitude" input box. 2. Enter the calculated longitude in the "Longitude" input box. 3. Enter the height above sea level in the "Height" input box. 4. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 89: Agent Ip

    Enter the subnet mask of the device. ● Default gateway Enter the IP address of the default gateway to be able to communicate with devices in another subnet, for example diagnostics stations, e-mail server. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 90: Restart

    In this menu, there is a button with which you can restart the device and the option of resetting to the factory setting or reset the default settings of various profiles. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 91 Which settings were set specially for a profile are displayed before the restart. The profiles can be used independently of the factory setting of the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 92 Click this button to restore the default settings of the Industrial Ethernet profile and to restart the device. You must confirm the restart in a dialog box. The dialog box displays these settings specially made for operation in the Industrial Ethernet environment. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 93: Load & Save

    OSS licenses Debug This file contains information for Siemens Support. It is encrypted and can be sent by e-mail to Siemens Support without any se- curity risk. Electronic Data Sheet (EDS) Electronic data sheet for describing devices in the EtherNet/IP mode Firmware The firmware is signed and encrypted.
  • Page 94: Http

    This WBM page is available both for connections using HTTP and for connections using HTTPS. Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with previous firmware versions with/without PLUG inserted During the installation of a previous version, the configuration data can be lost.
  • Page 95 With this button, you can delete files from the device. The button can only be enabled if this function is supported for the file type and the file exists on the device. Note Following a firmware update, delete the cache of your Internet browser. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 96 3. If individual settings are necessary for specific devices, these must be made online on the relevant device. Note Configuration data has a checksum. If you change the data, you can no longer upload it to the IE switch. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 97: Tftp

    TFTP server to the devices. This means, for example, that you can also load new firmware from a file located on a TFTP server. Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Note Incompatibility with previous firmware versions with/without PLUG inserted During the installation of a previous version, the configuration data can be lost.
  • Page 98 69 to your own requirements. The table has the following columns: ● Type Shows the file type. ● Description Shows the short description of the file type. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 99 2. Load this configuration file on all other devices you want to configure in this way. 3. If individual settings are necessary for specific devices, these must be made online on the relevant device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 100: Passwords

    The "Enabled" check box is selected but the password does not match the file or no file has been loaded yet. – '-' The password cannot be evaluated or is not yet being used. The "Enabled" check box is not selected. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 101: Events

    5.4.6.1 Configuration Selecting system events On this page, you specify how a device reacts to system events. To enable or disable the options, click the relevant check boxes of the columns. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 102 2 remain unchanged. ● Copy to table If you click the button, the setting is adopted for all events of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 103 The temperature has fallen below or exceeded a certain limit. ● E-mail The device sends an e-mail. This is only possible if the SMTP server is set up and the "SMTP client" function is enabled. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 104: Severity Filters

    – Log Table – Syslog – Faults 2. Click the "Set Values" button. 5.4.6.2 Severity Filters Setting the Severity Filters On this page, set the threshold levels for sending system event notifications. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 105: Smtp Client

    Internet browser using the identification of the sender to read out further diagnostics information. On this page, you can configure up to three SMTP servers and the corresponding e-mail addresses. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 106 ● SMTP Server Address Shows the IP address of the SMTP server. ● Receiver Email Address Enter the e-mail address to which the device sends an e-mail if a fault occurs. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 107: Dhcp

    IPv4 addresses. It is also possible to configure the server so that the client always receives the same IPv4 address in response to its request. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 108 If a configuration file is downloaded, this can trigger a system restart. If the currently running configuration and the configuration in the downloaded configuration file differ, the system is restarted. Make sure that the option "DHCP Client Configuration Request (Opt. 66, 67"is no longer set. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 109: Dhcp Server

    If there are devices in your network on which the echo service is disabled as default, there may be conflicts with the IPv4 addresses. To avoid this, assign these devices an IPv4 address outside the IPv4 address band used by the DHCP server. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 110 IPv4 address. When the entire time has elapsed, the DHCP client needs to request a new IPv4 address. Procedure Enable DHCP server globally 1. Select the "DHCP Server"" check box. 2. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 111: Port Range

    VLAN. If you add ports to the VLAN later, the ports are not automatically enabled in this tab. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 112: Dhcp Options

    1 the subnet mask is set automatically that you entered for the address band in "DHCP Server". With the DHCP option 3, you can set the internal IPv4 address of the device as a DHCP parameter using a check box. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 113 Select the check box in the row to be deleted. ● Pool ID Shows the number of the IPv4 address band. ● Option Code Shows the number of the DHCP option. ● Description Shows a description of the DHCP option. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 114 2. Enter the option code. 3. Click the "Create" button. 4. Enter a value. 5. If applicable for option 3 enable the "Use Interface IP" check box. 6. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 115: Relay Agent Information

    "Rebinding" message that the client sends automatically as a broadcast. • To speed up the release of an IPv4 address assigned via a relay agent, configure a shorter period of validity. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 116 Deleting an entry 1. Enable the "Select" check box in the row to be deleted. Repeat this for all entries you want to delete. 2. Click the "Delete" button. The entry is deleted. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 117: Static Leases

    Select the check box in the row to be deleted. ● Pool ID Shows the number of the IPv4 address band. ● Identification method Shows whether the client is identified by its MAC address or the client ID. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 118: Snmp

    Repeat this for all entries you want to delete. 2. Click the "Delete" button. The entry is deleted. 5.4.9 SNMP You should also refer to the chapter "Technical Basics", section "SNMP (Page 35)". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 119: General

    If you enable this option, SNMPv1/v2c can only read the SNMP variables. Note Community String For security reasons, do not use the standard values "public" or "private". Change the community strings following the initial installation. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 120 3. Enter the required character string in the "SNMPv1/v2c Read Community String" input box. 4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String" input box. 5. If necessary, enable the SNMPv3 User Migration. 6. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 121: Traps

    Creating a trap entry 1. In "Trap Receiver Address", enter the IP address of the station to which the device will send traps. 2. Click the "Create" button to create a new trap entry. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 122: Groups

    – no Auth/no Priv No authentication enabled / no encryption enabled. – Auth/no Priv Authentication enabled / no encryption enabled. – Auth/Priv Authentication enabled / encryption enabled. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 123 3. Click the "Create" button to create a new entry. 4. Specify the required read rights for the group in " Read". 5. Specify the required write rights for the group in " Write". 6. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 124: Users

    ID is added to every frame. This user name and the applicable security settings are checked by both the sender and recipient. Figure 5-5 SNMPv3 user - first part of the table SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 125 Enter the authentication password in the first input box. This password must have at least 6 characters, the maximum length is 32 characters. ● Authentication Password Confirmation Confirm the password by repeating the entry. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 126 6. Click the "Set Values" button. Delete user 1. Enable "Select" in the row to be deleted. Repeat this for all users you want to delete. 2. Click the "Delete" button. The entry is deleted. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 127: System Time

    Click the button to use the time setting of the PC. ● Last Synchronization Time Shows when the last time-of-day synchronization took place. If no time-of-day synchronization was possible, the box displays "Date/time not set". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 128 2. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY HH:MM:SS". 3. Click the "Set Values" button. The date and time are adopted and "Manual" is entered in "Last Synchronization Mechanism" box. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 129: Dst Overview

    With an entry of the type "Recurring", the period in which daylight saving time is active is displayed consisting of week, day, month and time of day. With an entry of the type "Date" a "-" is displayed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 130 – Hour (for start and end date) – Month (for start and end date) – Week (for start and end date) – Day (for start and end date) 7. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 131: Dst Configuration

    This setting is suitable for regions in which the daylight saving time always begins or ends on a certain weekday. ● Name Enter a name for the entry. The name can be a maximum of 16 characters long. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 132 Specify the month. ● End Date Enter the following values for the end of daylight saving time: – Day Specify the day. – Hour Specify the hour. – Month Specify the month. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 133 You can select the first to fourth or the last week of the month. – Day Specify the weekday. ● End Date Enter the following values for the end of daylight saving time: – Hour Specify the hour. – Month Specify the month. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 134: Sntp Client

    Enable or disable automatic time-of-day synchronization using SNTP. ● Current System Time Shows the current date and current normal time received from the server. If you specify a time zone, the time information is adapted accordingly. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 135 "Poll Interval[s]" are displayed to allow further configuration. With this type of synchronization, the device is active and sends a time query to the SNTP server. ● SNTP Server Address Enter the IP address of the SNTP server. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 136 6. In the "Poll Interval[s]" input box, enter the time in seconds after which a new time query is sent to the time server. 7. Click the "Set Values" button to transfer your changes to the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 137: Ntp Client

    Shows the current date and current normal time received by the IE switch. If you specify a time zone, the time information is adapted accordingly. ● Last Synchronization Time Shows when the last time-of-day synchronization took place. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 138 – 1025 to 36564 ● Poll Interval[s] Here, enter the interval between two time queries. In this box, you enter the query interval in seconds. Possible values are 64 to 1024 seconds. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 139: Simatic Time Client

    The page contains the following boxes: ● SIMATIC Time Client Select this check box to enable the device as a SIMATIC time client. ● Current System Time Shows the current system time. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 140 – SIMATIC Automatic time-of-day synchronization using the SIMATIC time frame Procedure 1. Click the "SIMATIC Time Client" check box to enable the SIMATIC Time Client. 2. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 141: Automatic Logout

    2. Enter a value of 60-600 seconds in the "CLI (TELNET, SSH, Serial) [s]" input box. If you enter the value 0, the automatic logout is disabled. 3. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 142: Button

    If you select the check box, you can activate or deactivate the "Redundancy Manager" function via the button. ● Set Fault Mask If you select the check box, you can define the fault mask via the button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 143: Syslog Client

    ● The IP address of the Syslog server is entered on the device. Description The page contains the following boxes: ● Syslog Client Enable or disable the Syslog function. ● Syslog Server Address Enter the IP address of the Syslog server. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 144 2. Create a new entry. Deleting an entry 1. Select the check box in the row to be deleted. 2. Click the "Delete" button. All selected entries are deleted and the display is refreshed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 145: Ports

    Shows the type of the port. The following types are possible: – Switch Port VLAN Hybrid – Switch Port VLAN Trunk ● Status Shows whether the port is on or off. Data traffic is possible only over an enabled port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 146 Shows whether flow control is enabled or disabled for the port. ● Flow Ctrl. Shows whether flow control is working on this port. ● MAC Address Shows the MAC address of the port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 147: Configuration

    The port is disabled and the connection to the partner device is terminated. Note Reduced current consumption For every optical port that you set to "link down", the current consumtion of the device is reduced by 30 mA. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 148 10 Mbps half duplex. Note "Auto negotiation" and Autocrossover • SCALANCE XB-200/SCALANCE XC-200: If you disable the "Auto negotiation" function, the "MDI/MDI-X" autocrossover function is also turned off. The use a crossover cable. • SCALANCE XP-200: If you disable the "Auto negotiation" function, the "MDI/MDI-X"...
  • Page 149 Optical ports only work with the full duplex mode and at maximum transmission rate. As a result, the following settings cannot be made for optical ports: • Automatic configuration • Transmission speed • Transmission technique SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 150: Fault Monitoring

    A fault causes the signaling contact to trigger and the fault LED on the device to light up and, depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log table. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 151: Link Change

    A fault causes the signaling contact to trigger and the fault LED on the device to light up and, depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log table. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 152 1. Select the required setting from the drop-down list of the "Setting"column. 2. Click the "Copy to table" button. The setting is adopted for all ports of table 2. 3. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 153: Redundancy

    Enable or disable connection monitoring. If the redundancy of the connection is lost, an error is signaled. 5.4.16 PROFINET Settings for PROFINET On this page, you configure the mode of PROFINET. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 154 Following this, the device can only be accessed via the serial interface, using the Primary Setup Tool or using DHCP. With the appropriate attachment, a previously correctly configured device can cause circulating frames after the reset and therefore the failure of the data traffic. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 155: Ethernet/Ip

    When EtherNet/IP is turned on, PROFINET is turned off. The switchover from EtherNet/IP and PROFINET has no effect on DCP. Note PROFINET AR Status If a PROFINET connection is established; in other words the PROFINET AR status is "Online", you cannot enable EtherNet/IP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 156: Plug

    If you decide against executing the function after making your selection, click the "Refresh" button. As a result the data of this page is read from the device again and the selection is canceled. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 157 This allows you to return to the previous, more up-to-date firmware without any loss of configuration data. If the original configuration on the PLUG is no longer required, the PLUG can be deleted or rewritten manually using "System > PLUG". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 158 The configuration in the internal flash memory of the device is copied to the PLUG. – Erase PLUG to factory default Deletes all data from the C-PLUG and triggers low-level formatting. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 159: Ping

    Click this button to start the ping function. ● Ping Output This box shows the output of the ping function. ● Clear Click this button to empty the "Ping Output" box. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 160: Power Over Ethernet (Poe)

    Sum of the power used by the end devices. ● Usage Threshold [%] As soon as the power being used by the end devices exceeds the percentage shown here, an event is triggered. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 161: Port

    Here, you can enter a string to describe the connected device in greater detail. The maximum length is 255 characters. ● Use Custom Maximum Power Select whether the custom maximum power is used. If "No Change" is selected, the entry in table 2 remains unchanged. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 162 Here, you can enter a string to describe the connected device in greater detail. The maximum length is 255 characters. ● Use Custom Maximum Power If you enable this check box for a port, the user-defined maximum power is used. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 163 Shows the power that the SCALANCE provides for this port. ● Voltage [V] (read-only) Shows the voltage applied to this port. ● Current [mA] (read-only) Shows the current with which a device connected to this port is supplied. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 164: Port Diagnostics

    Automatic re-establishment of the connection can fail and then needs to be done manually. Description The page contains the following boxes: ● Port Select the required port from the drop-down list. ● Run Test Activates error diagnostics. The result is shown in the table. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 165 Displays the status of the cable. ● Distance Displays the distance to the cable end, cable break, or short-circuit in meters. The value for the distance has a tolerance of +/- 1 m. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 166: Sfp Diagnostics

    Shows the name of the interface. ● Model Shows the type of interface. ● Revision Shows the hardware version of the SFP. ● Serial Shows the serial number of the SFP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 167 ● Tx Power [μW] Shows the transmit power of the interface [μW]. ● Current column Shows the current value. ● Low column Shows the lowest value. ● High column Shows the highest value. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 168: The "Layer 2" Menu

    If you select this option, you specify the required redundancy mode in the "Redundancy Mode" drop-down list. – Ring If you select this option, you specify the required redundancy mode in the "Redundancy Mode" drop-down list. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 169 – STP Enables the Spanning Tree Protocol (STP). Typical reconfiguration times with spanning tree are between 20 and 30 seconds. You can configure other settings in "Layer 2 > Spanning Tree". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 170 GMRP and IGMP cannot operate at the same time. ● GVRP Enable or disable "GVRP" (GARP VLAN Registration Protocol). You can configure other settings in "Layer 2 > VLAN > GVRP". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 171: Quality Of Service (Qos)

    Specify the priority of agent frames. The switch sorts the frame into a queue according to this prioritization . You configure the assignment of the priority to a queue on the page ""Layer 2 > QoS > CoS Map". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 172: Cos Map

    2. In the "Scheduling Mode" drop-down list select the method according to which the processing order of the frames is decided. 3. Click the "Set Values" button. 5.5.2.2 CoS Map CoS Map On this page, you can assign CoS priorities to different queues. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 173: Dscp Map

    1. For each value in the "CoS" column, select the queue from the "Queue" drop-down list. 2. Click the "Set Values" button. 5.5.2.3 DSCP Map DSCP queue On this page, you can assign DSCP priorities to different Queues. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 174 ● DSCP codes 48 - 63 → Queue 4 Steps in configuration 1. For each value in the "DSCP" column, select the queue from the "Queue" drop-down list. 2. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 175: Qos Trust

    Table 2 has the following columns: ● Port Shows the configurable ports. The port is made up of the module number and the port number, for example port 0.1 is module 0, port 1. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 176 If it contains a VLAN tag, the switch sorts it into a queue according to this prioritization. If the frame contains neither a DSCP prioritization nor a VLAN tag, the switch sorts the frame into a queue according to the prioritization of the receiving port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 177: Cos Port Remap

    Select the priority with which a frame will be sent. – No Change No change in table 2. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 178: Rate Control

    Limiting the transfer rate of incoming and outgoing data On this page, you configure the load limitation for the individual ports. You can specify the category of frame for which these limit values will apply. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 179 When you input, note that the WBM rounds to correct values. If values are configured for Total Ingress Rate and Egress Rate, the actual values in operation can deviate slightly from the set values. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 180: Vlan

    Changing the Agent VLAN ID If the configuration PC is connected directly to the device via Ethernet and you change the agent VLAN ID, the device is no longer reachable via Ethernet following the change. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 181 Length: max. 32 characters ● State Shows the status type of the entry in the internal port filter table. Here, "Static" means that the VLAN was entered statically by the user. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 182 ● All static and dynamic unicast entries are deleted. ● All static and dynamic multicast entries are deleted. ● With spanning tree you can set the following protocol compatibility: STP, RSTP and MSTP. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 183 5. Specify the use of the port in the VLAN. If, for example you select "M", the port is a member of the VLAN. Frames sent in this VLAN are forwarded with the corresponding VLAN tag. 6. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 184: Gvrp

    Disables the sending of GVRP frames. – No change No change to table 2. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 185: Port-Based Vlan

    On this page, you specify the configuration of the port properties for receiving frames. You can only configure the settings on this page if on the "General" tab you selected the "Base Bridge Mode" "802.1Q VLAN Bridge". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 186 The VLAN ID of received frames decides whether they are forwarded: To forward a VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames from unknown VLANs are discarded at the receiving port. – Disabled All frames are forwarded. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 187: Mirroring

    If in a VLAN you select more than one source port for the port-based egress mirroring, unknown unicast and multicast frames as well as broadcast frames are forwarded only once to the destination port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 188 If mirroring is disabled, the listed port-specific functions are reset to the default values. This reset takes place regardless of whether the functions were configured manually or automatically by enabling Monitor Barrier. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 189 5. Change to the following tab to make further detailed settings for the session ID. Deleting a mirroring session 1. Click the check box in the first column to select the row. 2. Click the "Delete" button to delete the selected rows. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 190: Port

    1. In the table, click the check box of the row after the port to be mirrored. Select whether you want to monitor incoming or outgoing packets. To monitor the entire data traffic of the port, select both check boxes. 2. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 191: Dynamic Mac Aging

    15, the value is automatically rounded down. Steps in configuration 1. Select the "Dynamic MAC Aging" check box. 2. Enter the time in seconds in the "Aging Time[s]" input box. 3. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 192: Ring Redundancy

    "MRP Auto Manager" setting negotiate among themselves to establish which device adopts the role of "MRP Manager". The device with the lowest MAC address will always become "MRP Manager". The other devices automatically set themselves to "MRP Client" mode. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 193 P0.7 and P0.8 SCALANCE XB213-3 P0.15 and P0.16 SCALANCE XC206-2SFP, XC208, XC216 and P0.1 and P0.2 XC224 SCALANCE XC206-2 P0.7 and P0.8 SCALANCE XP208 P0.1 and P0.2 SCALANCE XP216 P0.10 and P0.12 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 194 If you used other ports previously as ring ports before resetting, a previously correctly configured device can cause circulating frames and therefore the failure of the data traffic. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 195: Standby

    This identifies the two modules that belong together as standby partners. Note To be able to use the function, HRP must be activated. The standby manager always requires an activated HRP client or HRP manager. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 196 MAC addresses, the previous device with the slave function can take over the role of the standby master. Note If two devices are linked by standby, the "Standby" function must be enabled on both devices. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 197: Spanning Tree

    The page contains the following boxes: ● Spanning Tree Enable or disable Spanning Tree. ● Protocol Compatibility Select the protocol compatibility. The following settings are available: – STP – RSTP – MSTP SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 198: Cist General

    Root Bridge. The lower the value, the higher the priority. If several devices in a network have the same priority, the device whose MAC address has the lowest numeric value will become the root bridge. Both parameters, bridge priority SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 199 For a description, see Bridge Priority / Root Priority ● Regional Root Address The MAC address of the device. ● Regional Root Cost The path costs from this device to the root bridge. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 200: Cist Port

    MSTP-CIST port configuration When the page is called, the table displays the current status of the configuration of the port parameters. To configure them, click the relevant cells in the port table. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 201 Range of values: 0 - 240. The default is 128. ● Cost Calc. Enter the path cost calculation. If you enter the value "0" here, the automatically calculated value is displayed in the "Path costs" box. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 202 Select this option when there is always an end device on this port. Otherwise a reconfiguration of the network will be triggered each time a connection is changed. – Auto Select this option if you want a connected end device to be detected automatically at SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 203 The port-specific setting of the Hello time is only possible with Protocol compatibility MSTP. If the "Protocol compatibility RSTP is set, the "Bridge Hello Time" parameter on the page "Layer 2 > Spanning Tree > CIST General" page is used. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 204: Mst General

    ● MSTP instance ID Shows the number of the MSTP instance. ● Root Address Shows the MAC address of the root bridge. ● Root Priority Shows the priority of the root bridge. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 205: Mst Port

    5.5.8.5 MST Port Configuration of the Multiple Spanning Tree port parameters On this page, you set the parameters for the ports of the configured multiple spanning tree instances. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 206 ● Cost Calc. Enter the path cost calculation in the input box. If you enter the value "0" here, the automatically calculated value is displayed in the next box "Path Costs". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 207 1. In the input cells of the table row, enter the values of the port you are configuring. 2. From the drop-down lists of the cells of the table row, select the values of the port you are configuring. 3. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 208: Enhanced Passive Listening Compatibility

    ● Enhanced Passive Listening Compatibility Enable or disable this function for the entire device. Steps in configuration 1. Enable or disable "Enhanced Passive Listening Compatibility" 2. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 209: Loop Detection

    ● Threshold value / Remote reaction / Local reaction Make the required settings. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 210 This requires that the "VLAN Loop Detection" check box is selected. ● Reset After a loop in the network has been eliminated, click the "Reset" button to reset the port again. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 211: Link Aggregation

    If the port in the link aggregation becomes active, individual port configurations such as DCP forwarding are overwritten with the configured values of the link aggregation. Display of the configured aggregation This page displays all the configured link aggregations. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 212 The link aggregation sends tagged and untagged frames. It is not automatically a member of a VLAN. – Trunk The link aggregation only sends tagged frames and is automatically a member of all VLANs. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 213 3. Click the "Set Values" button. Deleting a link aggregation 1. Select the check box in the row to be deleted. Repeat this for all entries you want to delete. 2. Click the "Delete" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 214: Dcp Forwarding

    Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 215: Configuration Manual, 07/2016, C79000-G8976-C360-04

    Network components that support LLDP have an LLDP agent. The LLDP agent sends information about itself and receives information from connected devices at periodic intervals. The received information is stored on the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 216 This port can only send LLDP frames. – Rx & Tx This port can receive and send LLDP frames. – "-" (disabled) This port can neither receive nor send LLDP frames. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 217: Fiber Monitoring Protocol

    If you have enabled fiber monitoring and a pluggable transceiver with diagnostics capability is pulled, fiber monitoring is automatically disabled for this port and the set limit values and a possibly pending error status are deleted. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 218 ● Power Loss [dB] maintenance demanded (Critical) Specify the value at which you are informed of the power loss of the connection by a message of the severity level "Critical" Default: -55 dB SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 219: Unicast

    The displayed boxes depend on which "Base bridge mode" is set. If you change the "Base bridge mode" the existing entries are lost. Figure 5-7 Base bridge mode: 802.1Q VLAN Bridge SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 220 Shows the port via which the node with the specified address can be reached. Frames received by the device whose destination address matches this address will be forwarded to this port. Note You can only specify one port for unicast addresses. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 221: Locked Ports

    The port accepts only static MAC addresses that were created previously either manually or with the "Start learning" function and the "Stop learning" function. To enter all connected nodes automatically, there is a function for automatic learning (see "Layer 2 > Unicast > Learning"). SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 222 Steps in configuration Enabling access control for an individual port 1. Select the check box in the relevant row in table 2. 2. To apply the changes, click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 223: Learning

    The device now enters the addresses of connected devices until you stop the function. 2. Click the "Stop learning" button to stop the learning function. The button is once again replaced by the "Start learning" button. The learned entries are stored. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 224: Unknown Unicast Blocking

    Blocking of unicast frames is disabled. – No change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 225: Multicast

    For some applications, there are fixed multicast addresses (NTP, IETF1 Audio, IETF1 Video etc.). SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 226 The displayed boxes depend on which "Base bridge mode" is set. If you change the "Base bridge mode" the existing entries are lost. Figure 5-9 Base bridge mode: 802.1Q VLAN Bridge Figure 5-10 Base bridge mode: 802.1D transparent bridge SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 227 (IGMP) Member of the multicast group, registration was by an IGMP frame. This value is only dynamically assigned. – – Not a member of the multicast group. No multicast frames with the defined multicast MAC address are sent via this port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 228: Igmp

    IGMP are deleted from the address table if they are not updated by a new IGMP frame. This applies to all ports; a port-specific configuration is not possible. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 229 1. Select the "IGMP Snooping" check box. 2. Enter the value for the aging time in seconds in the "IGMP Snooping Aging Time" box. 3. Select the "IGMP Querier" check box. 4. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 230: Gmrp

    Disables the sending of GMRP frames. – No change Table 2 remains unchanged. ● Copy to table If you click the button, the settings are adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 231: Multicast Blocking

    4. To apply the changes, click the "Set Values" button. 5.5.15.4 Multicast blocking Disabling the forwarding of unknown multicast frames On this page, you can block the forwarding of unknown multicast frames for individual ports. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 232 1. In the "Setting" drop-down list, select the "Enabled" entry. 2. Click the "Copy to table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 233: Broadcast

    The blocking of broadcast frames is disabled. – No change Table 2 remains unchanged. ● Copy to Table If you click the button, the setting is adopted for all ports of table 2. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 234 1. In the "Setting" drop-down list in table 1, select the "Enabled" entry. 2. Click the "Copy to Table" button. The check box is enabled for all ports in table 2. 3. To apply the changes, click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 235: Rmon

    Note If you disable RMON, these statistics are not deleted but retain their last status. ● Port Select the ports for which statistics will be displayed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 236: History

    On this page, you can specify whether or not samples of the statistics are saved for a port. You can specify how many entries should be saved and at which intervals samples should be taken. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 237 If you click the button, the settings are adopted for all ports of table 2. Table 2 has the following columns: ● Port Shows the port to which the settings relate. ● Setting Enable or disable the recording of the history on the relevant port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 238 3. Click the "Copy to Table" button. The settings are adopted for all ports of table 2. 4. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 239: The "Layer 3" Menu

    Enter the IPv4 address of the DHCP server. The table has the following columns: ● Select Select the row you want to delete. ● Server IP Address Shows the IPv4 address of the DHCP server. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 240: Option

    ID. ● Circuit ID Receive VLAN ID Enable or disable the check box. If you enable the check box, the VLAN ID is added to the generated circuit ID. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 241 If you use "Free Number", you can enter the ID for "Circuit ID". ● Circuit ID Enter the circuit ID. The box can only be edited if you select the "Free Number" entry for the "Circuit ID Type". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 242: The "Security" Menu

    RADIUS server. You configure how the authentication is handled on the "Security > AAA > General" page. Note When you transfer the configuration of a device to STEP 7 (TIA Portal), the configured users are not transferred. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 243 – The port VID of the port is changed to the ID of the assigned VLAN. Note If the port is only to be assigned to one VLAN, you need to adapt the VLAN configuration manually. As default, all ports are untagged members in "VLAN 1". SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 244: Users

    5.7.2 Users 5.7.2.1 Local Users Local users On this page, you create local users with the corresponding rights. Note The values displayed depend on the rights of the logged-in user. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 245 You configure the password policy of the device on the page "Security > Passwords > Options". ● Password Enter the password. The strength of the password depends on the set password policy. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 246 5. Click the "Create" button. Deleting users 1. Select the check box in the row to be deleted. 2. Click the "Delete" button. The entries are deleted and the page is updated. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 247: Passwords

    Shows the user that is currently logged in. ● Current User Password Enter the password for the currently logged in user. ● User Account Select the user whose password you want to change. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 248 3. Enter the new password for the selected user in the "New Password" input box. 4. Repeat the new password in the "Password Confirmation" input box. 5. Click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 249: Options

    Login of network nodes The designation used "AAA"" stands for "Authentication, Authorization, Accounting". This feature is used to identify and allow network nodes and to make the corresponding services available to them. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 250 RADIUS request is sent. – RADIUS and fallback Local The authentication must be handled via a RADIUS server. A local authentication is performed only when the RADIUS server cannot be reached in the network. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 251: Radius Client

    Here, enter the input port on the RADIUS server. As default, input port 1812 is set. Range of values: 1 - 65535 ● Shared Secret Enter the access identifier of the RADIUS server. Range of values: 1 ... 128 characters SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 252 The following default values are entered in the table: – Auth. Server Type: Login & 802.1X – RADIUS Server Address: 0.0.0.0 – Server Port: 1812 – Max. Retrans.: 3 – Primary server: No SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 253 1. Click the check box in the first column before the row you want to delete to select the entry for deletion. Repeat this for all entries you want to delete. 2. Click the "Delete" button. All selected entries are deleted and the display is refreshed. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 254: Authenticator

    By enabling the relevant options , you specify for each port whether or not network access protection according to IEEE 802.1X is enabled on this port. Figure 5-11 802.1x Authenticator - first part of the table SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 255 If "No Change" is selected, the entry in table 2 remains unchanged. ● RADIUS VLAN Assignment Allowed Select the required setting. If "No Change" is selected, the entry in table 2 remains unchanged. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 256 "802.1X procedure is 5 seconds. If manual input is necessary at a port for the authentication with the 802.1X" procedure, the 5 seconds may not be not adequate. To be able to run authentication using "802.1X", disable the MAC authentication on this port. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 257 Steps in configuration Enabling authentication for an individual port 1. Select the required options in the relevant row in table 2. 2. To apply the changes, click the "Set Values" button. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 258: Management Acl

    You should therefore configure an access rule that allows access to the management before you enable the function. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 259 Specify whether the station (or the IPv4 address) can access the device using the TELNET protocol. ● HTTP Specify whether the station (or the IPv4 address) can access the device using the HTTP protocol. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 260 2. Click the "Set Values" button to enable the configured access rules. Change rule 1. Configure the data of the rule you want to change. 2. Click the "Set Values" button to transfer the changes to the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 261 1. Select the check box in the row to be deleted. 2. Repeat this procedure for every entry you want to delete. 3. Click the "Delete" button. The rules are deleted and the page is updated. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 262 Configuring with Web Based Management 5.7 The "Security" menu SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 263: Troubleshooting/Faq

    Troubleshooting/FAQ Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Operating the button To load new firmware, you require the button. When pressing the button, remember the information in the appropriate operating instructions.
  • Page 264 "Control Panel" > "Programs and Features" > "Turn Windows features on or off" > "TFTP Client". 8. Once the firmware has been transferred completely to the device and validated, there is an automatic restart on the device. This may take several minutes. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 265: Message: Sinema Configuration Not Yet Accepted

    The configuration is saved on the device. The message is no longer visible in the display area. A configuration change directly on the device is no longer lost due to a restart of the device. SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 266 Troubleshooting/FAQ 6.2 Message: SINEMA configuration not yet accepted SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 267: Index

    Forward Delay, 199 Formatting, 158 Saving the configuration, 158 CRC, 68 Geographic coordinates, 87 Glossary, 9 GMRP, 230 DCP forwarding, 214 GVRP, 184 DCP server, 84 DHCP Client, 107 Server, 109 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 268 PROFINET, 20, 153 Management ACL, 258 PROFINET IO, 20 Manufacturer, 51 PST, 214 Mirroring, 35 General, 187 Port, 190 MSTP, 197, 204 QoS, 175 Port, 200 QoS Trust, 34 Port parameters, 205 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 269 VLAN ID, 34 Information, 56 VLAN tag, 33 MSTP, 197 RSTP, 197 Spanning Tree Rapid Spanning Tree, 23 Web Based Management, 39 Requirement, 39 Server, 83 Web Based Management (WBM), 263 SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...
  • Page 270 Index SCALANCE XB-200/XC-200/XP-200 Web Based Management Configuration Manual, 07/2016, C79000-G8976-C360-04...

This manual is also suitable for:

Scalance xc-200Scalance xp-200

Table of Contents