Security and authentication
11.4 IP access control list
Parameter
mask
dscp
value
ack
rst
Result
The IP access list for TCP segments has been configured.
Note
Subnet mask for individual hosts
If you create the rule for a single system (one IP address), you will need to specify a 32-Bit
long subnet mask. This is then "255.255.255.255". As an alternative, you can specify the
keyword "host" followed by the IP address.
Further notes
You delete an IP access control list with the
command.
You display the configuration of the access control list with the
11.4.3.7

permit udp

Description
With this command, you configure an IP access control list for the UDP protocol.
You have the following options:
● All incoming and/or outgoing UDP datagrams are forwarded.
● Incoming and/or outgoing UDP datagrams of a specific host are forwarded.
● Incoming and/or outgoing UDP datagrams of hosts of a specific subnet are forwarded.
● Incoming and/or outgoing UDP datagrams are forwarded to specific ports.
Note
Processing order of the lists
The access control lists are processed on the interface in the order in which they were
created.
The index number of the access control list is not used for this.
510
Description
Corresponding subnet mask
Keyword for the Differentiated Services
Codepoint
Value for the Differentiated Services Codepoint 0 ... 63
Blocks ACK segments
Blocks RST segments
Values
IP address and subnet mask.
-
-
-
no ip access-list standard <acl-num>
show access-lists
SCALANCE XM-400/XR-500 Command Line Interface