Diagnostics
12.1 Event and fault handling
Parameter
cold-warmstart
linkchange
authentication-
failure
rmon-alarm
power-change
rm-state-change
standby-state-change
faultstate-change
stp-change
vrrp-state-change
loopd-state-change
ospf-state-change
all
logtable
syslog
email
trap
faults
all
Result
The setting deciding which message of the device is stored or forwarded is configured.
Further notes
You display the status of the events and the clients with the
You delete the settings with the
With this command, the clients are not enabled.
To enable the clients, use the
Note
Changing several message types or clients
With each command call, you can only select one message type and one client.
If you want to process several message types or clients, it may be more efficient to first
select the
556
Description
Message if there is cold or warm restart
Message when there is a status change on a physical interface
Message if there is an incorrect login
Message when there is a RMONalarm
Message when there is a status change in the power supply
Message when there is a status change in the redundancy manager
Message when there is a status change on a standby connection
Message when there is a status change in the error monitoring
Message when there is a change in the spanning tree
Message on status change of VRRP routers
Message if there is a status change in the detection of network loops
Message on status change of OSPF routers
All messages
Client that processes the logbook entries
Client that sends the messages to the log server
Client that sends the e-mails
Client that sends the SNMP traps
Error LED lights up. The setting is possible only for a cold or warm restart.
All clients at once
no event config
client config
option and then disable individual elements.
all
show events config
command.