Summary of Contents for Siemens SIMATIC NET SCALANCE X-300M

  • Page 1 ___________________ SCALANCE X-300M Introduction ___________________ Safety notes ___________________ SIMATIC NET Description ___________________ Assembling Industrial Ethernet switches SCALANCE X-300M ___________________ Connecting ___________________ Technical data Compact Operating Instructions ___________________ Dimension drawings ___________________ Approvals 10/2014 A5E02630801-06...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Introduction to the X-300M ....................... 5 Product group X-300M ......................7 Type designation ........................8 Safety notes ............................9 Important notes on using the SCALANCE X-300 product family ..........9 Important notes on using the device in hazardous areas ............11 Description ............................
  • Page 4 Table of contents Power supply .......................... 38 5.4.1 Power supply - general ......................38 5.4.2 12 / 24 VDC - product group X-300M ..................38 5.4.3 Connecting the power supply ....................39 Technical data ............................41 Construction, installation and environmental conditions ............41 Connectors and electrical data ....................
  • Page 5: Introduction

    Introduction Introduction to the X-300M Purpose of the Operating Instructions (compact) These operating instructions (compact) contain information with which you will be able to install and connect up a device of the SCALANCE X-300 product line. Validity of these Operating Instructions (compact) These Operating Instructions (compact) are valid for the product group X-300M of the SCALANCE X-300 product line (see product overview).
  • Page 6: Compact Operating Instructions, 10/2014, A5E02630801

    Security messages Note Siemens offers IT security mechanisms for its automation and drive product portfolio in order to support the safe operation of the plant/machine. Our products are also continuously developed further with regard to IT security. We therefore recommend that you regularly check for updates of our products and that you only use the latest versions.
  • Page 7: Product Group X-300M

    Introduction 1.2 Product group X-300M Product group X-300M Device Properties Order number X308-2M 1 x 24 VDC 6GK5 308-2GG00-2AA2 4 x 10/100/1000 Mbps, RJ-45 ports electrical 2 x 100/1000 Mbps for 2-port media modules LEDs, connector power supply and data cable outlet on front Diagnostics port at rear X308-2M TS...
  • Page 8: Type Designation

    Introduction 1.3 Type designation Type designation Structure of the type designation The type designation of an IE Switch X-300 is made up of several parts that have the following meaning: Interfaces of devices without optical ports: Interface Property Electrical RJ-45 port for 10/100 Mbps. Electrical RJ-45 port for 10/100 Mbps or 10/100/1000 Mbps.
  • Page 9: Safety Notes

    Safety notes Important notes on using the SCALANCE X-300 product family Safety notices on the use of the device The following safety notices must be adhered to when setting up and operating the device and during all associated work such as installation, connecting up, replacing or opening the device.
  • Page 10 Safety notes 2.1 Important notes on using the SCALANCE X-300 product family General notices about use in hazardous areas WARNING Risk of explosion when connecting or disconnecting the device EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
  • Page 11: Important Notes On Using The Device In Hazardous Areas

    Safety notes 2.2 Important notes on using the device in hazardous areas WARNING Protection against transient voltage surges Provisions shall be made to prevent the rated voltage from being exceeded by transient voltage surges of more than 40%. This criterion is fulfilled, if supplies are derived from SELV (Safety Extra-Low Voltage) only.
  • Page 12 Safety notes 2.2 Important notes on using the device in hazardous areas SCALANCE X-300M Compact Operating Instructions, 10/2014, A5E02630801-06...
  • Page 13: Description

    Description Unpacking and checking Unpacking, checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use damaged parts, this can lead to the following problems: •...
  • Page 14: Product Group X-300M

    Description 3.3 Product group X-300M Product group X-300M 3.3.1 SCALANCE X308-2M and X308-2M TS Possible attachments The SCALANCE X308-2M and X308-2M TS are partly modular devices and each has 8 ports. ● 4 fixed ports in the base device: 4 electrical RJ-45 jacks (with securing collars) for connection of end devices or other network segments.
  • Page 15 Description 3.3 Product group X-300M Possible attachments (example) CAUTION Use only approved media modules in the module slots The connection of end devices or other network segments does not depend on the module slot, but rather on the selected media module. Refer to the section Media module installation in slot.
  • Page 16: The Set / Select Button

    Description 3.4 The SET / SELECT button The SET / SELECT button The SET/SELECT button is located on the top of the housing of devices of the X-300 EEC series. On all other devices, this button is on the front panel of the housing beside the LED display.
  • Page 17: Led Display

    Description 3.5 LED display LED display The "RM" LED for the "redundancy manager" function The "RM" LED indicates whether or not the device is operating in the role of redundancy manager and whether or not the ring is operating error-free. LED color LED status Meaning...
  • Page 18 Description 3.5 LED display The "DM" LED for the display mode The "DM" LED (Display Mode) indicates which of the four display modes A, B, C or D is currently active. The meaning of the L1, L2 and P1, P2, ... LEDs depends on the display mode.
  • Page 19 Description 3.5 LED display Meaning in display mode D Color Status Meaning X308-2M (24 VDC) X308-2M TS (12 VDC) L1 / L2 Power supply L1 / L2 is not Power supply L1 / L2 falls monitored. If L1 / L2 falls below 12 V, below 17 V * , the signaling...
  • Page 20 Description 3.5 LED display Meaning in display mode B LED color LED status Meaning Port operating at 10 Mbps. green Port operating at 100 Mbps. orange Port operating at 1000 Mbps. If there is a problem on the connection and the type of transmission is fixed (autonegotiation off), the desired status, in other words the set transmission speed (1000 Mbps, 100 Mbps, 10 Mbps) continues to be displayed.
  • Page 21: Area Of Application And Function Of The C-Plug

    Description 3.6 Area of application and function of the C-PLUG Area of application and function of the C-PLUG Area of application The C-PLUG (configuration plug) that ships with the product is an exchangeable memory medium for storing the configuration data of the device. The device can also be operated without a C-PLUG.
  • Page 22: Removing And Inserting The C-Plug (Compact Housing)

    Description 3.7 Removing and inserting the C-PLUG (compact housing) Removing and inserting the C-PLUG (compact housing) NOTICE A C-PLUG may only be removed or inserted when the device is turned off. Position of the C-PLUG In devices with a compact housing, the C-PLUG is located behind the sealing screw on the rear of the device.
  • Page 23: Assembling

    Assembling Installation WARNING Suitable installation location at temperatures above 50 °C If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. When installing the device, select a location where only qualified service personnel or trained users have access to it.
  • Page 24: Installation Options

    Assembling 4.2 Installation options Installation options Installing the switches IE Switches X-300 can be installed in various ways: ● Installation on a 35 mm DIN rail ● Installation on a SIMATIC S7-300 standard rail ● Wall mounting ● 19" rack mounting (SCALANCE XR300) For the possible types of installation, refer to the section "General installation (Page 25)".
  • Page 25: General Installation

    Assembling 4.3 General installation General installation 4.3.1 Installation on a DIN rail WARNING When used in shipbuilding, installation on a 35mm DIN rail is not permitted. The 35 mm DIN rail (DIN EN 60715) does not provide adequate support in shipping or when there is severe vibration (>...
  • Page 26 Assembling 4.3 General installation Removing To remove an IE Switch X-300 from the DIN rail: 1. Disconnect all cables from the switch. 2. Release the lower part of the IE Switch X-300 from the DIN rail with a screwdriver and pull the lower part of the switch away from the DIN rail.
  • Page 27: Installation On A Standard Rail

    Assembling 4.3 General installation 4.3.2 Installation on a standard rail Installation on a SIMATIC S7-300 standard rail 1. Place the upper guide at the top of the IE Switch X-300 housing in the S7 standard rail. 2. Screw the IE Switch X-300 to the underside of the standard rail. 3.
  • Page 28: Wall Mounting

    Assembling 4.3 General installation 4.3.3 Wall mounting Wall mounting 1. For wall mounting, use suitable mounting fittings for the wall (for example, for a concrete wall, four plugs 6 mm diameter and 30 mm long, 4 screws 3.5 mm diameter and 40 mm long). 2.
  • Page 29: Installation Of Modular Devices

    Connecting media modules and SFP transceivers NOTICE Use only approved SFPs If you use components not approved by Siemens AG, in particular SFPs, Siemens cannot accept any responsibility for the correct functioning of the "Ethernet switch system" according to the specification.
  • Page 30 Assembling 4.4 Installation of modular devices CAUTION Remember the orientation of media modules. On modular devices, there are always two module slots arranged opposite each other. Remember the correct orientation when installing MM900 media modules. Example: • The first MM900 media module is installed in slot 3. •...
  • Page 31 Assembling 4.4 Installation of modular devices Installing a media module The media module is inserted with the handle pulled out. When the handle is inserted, the media module is locked in the device. Note The figures in the following installation instructions show the installation of a media module in a rack device.
  • Page 32 Assembling 4.4 Installation of modular devices Push the handle back into the media module. This locks the media module in the device. Insert the connectors. Removing a media module CAUTION Risk of burns due to the high temperature of the module housing Before removing an MM900 media module, turn the switch off and allow the device to cool down first.
  • Page 33: Sfp Installation In Sfp Media Module

    NOTICE Use only approved SFPs If you use SFPs that are not approved by Siemens AG, there is no guarantee that the device will function according to the specification. If you use unapproved SFPs, this can lead to the following problems: •...
  • Page 34 Assembling 4.4 Installation of modular devices Select the required SFP media module in the slot of the device. (Example: X-308-2M, slot 2) Insert the SFP with the clip closed in the SFP media module. Notice: Closing the clip after insertion does not lock the device in the rack.
  • Page 35: Connecting

    Connecting WARNING Before connecting up and commissioning the device, read the information in the section Safety notes (Page 9) Notes on commissioning Note Commissioning devices with redundancy mechanisms If you use redundancy mechanisms ("HRP" media redundancy or "MRP" and/or redundant coupling of rings over standby coupling), open the redundant path before you insert a new or replacement device in an operational network.
  • Page 36: Connecting Functional Ground

    Connecting 5.2 Connecting functional ground Connecting functional ground Installation on a DIN rail The device is grounded over the DIN rail. S7 standard rail The device is grounded over its rear panel and the neck of the screw. Wall mounting The device is grounded by the securing screw in the unpainted hole.
  • Page 37: Connecting The Signaling Contact

    Connecting 5.3 Signaling contact 5.3.1 Connecting the signaling contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact can be subjected to a maximum load of 100 mA (safety extra low voltage SELV 12 VDC / 24 VDC). Table 5- 1 Pin assignment of the signaling contact Pin number...
  • Page 38: Power Supply

    Connecting 5.4 Power supply Power supply 5.4.1 Power supply - general WARNING Danger to life: 100 ... 240 V power supply possible. Please note that the devices may have a 100 to 240 V or a 24 V power supply. You can recognize the type of power supply on the type plate, a warning on the device and the labeling of the connector to the power supply.
  • Page 39: Connecting The Power Supply

    Connecting 5.4 Power supply 5.4.3 Connecting the power supply 24 V safety extra-low voltage (SELV) WARNING • The IE Switch X-300 is designed for operation with safety extra-low voltage (SELV). This means that only SELV complying with IEC 60950-1 / EN60950-1 / VDE0805 can be connected to the power supply terminals.
  • Page 40 Connecting 5.4 Power supply Terminal block assignment (4-pin) Table 5- 3 Pinout of the safety extra-low voltage (SELV) Pin number Assignment (24 VDC) Assignment (12 VDC) Labeling (example) Pin 1 L1+ (24 VDC) L1+ (12 VDC) Pin 2 Pin 3 Pin 4 L2+ (24 VDC) L2+ (12 VDC)
  • Page 41: Technical Data

    Technical data Note Validity of the technical specifications All the technical specifications described in this section that is not assigned to a specific device variant, version or a media module, apply to all device variants/versions of the product group. Construction, installation and environmental conditions Table 6- 1 Construction Dimensions (W x H x D)
  • Page 42 Technical data 6.1 Construction, installation and environmental conditions Table 6- 4 Operating temperature depending on the media modules used Media module Installation Operating temperature direction Without media module Horizontal -40 °C to +70 ℃ Vertical -40 °C to +50 ℃ MM992-2CUC Horizontal -40 °C to +70 ℃...
  • Page 43: Connectors And Electrical Data

    Technical data 6.2 Connectors and electrical data Connectors and electrical data Table 6- 5 Connection for end devices or network components Max. number 8 ports Electrical (via twisted-pair) 4 x RJ-45 jacks with MDI-X assignment 10/100/1000 Mbps (half / full duplex) Media module slots 4 x modular (2 ports per slot)
  • Page 44 Technical data 6.2 Connectors and electrical data Table 6- 9 Electrical data: Signaling contact Device version Voltage via signaling contact Switching capacity (resistive load) (power supply) 12 VDC 12 VDC / 24 VDC Max. 100 mA 24 VDC 24 VDC Max.
  • Page 45: Cable Lengths

    Technical data 6.3 Cable lengths Cable lengths Table 6- 11 Permitted cable lengths (copper cable - Fast Ethernet) Cable type Accessory (plug, outlet, Permitted cable length TP cord) IE TP torsion cable with IE FC Outlet RJ-45 0 to 45 m + 10 m TP cord + 10 m TP cord with IE FC RJ-45 Plug 180...
  • Page 46: Other Properties

    Technical data 6.4 Other properties Other properties Table 6- 13 Switching properties Max. number of learnable addresses 8000 Aging time 30 sec Switching technique Store and forward Latency 5 μs Table 6- 14 Reconfiguration times for redundancy mechanisms Redundancy mechanism Reconfiguration times 300 ms Standby link...
  • Page 47 Technical data 6.4 Other properties Note The IE Switches X-300 support "full wire speed switching" complying with IEEE 802.3 on all ports. The number of packets therefore depends on the packet length. Note The following applies to IE Switches X-300: The number of IE Switches X-300 connected in a line influences the frame delay time.
  • Page 48 Technical data 6.4 Other properties SCALANCE X-300M Compact Operating Instructions, 10/2014, A5E02630801-06...
  • Page 49: Dimension Drawings

    Dimension drawings X-300M dimension drawings Note The following dimension drawings are available for the X-300M product group. Figure 7-1 X308-2M dimension drawing SCALANCE X-300M Compact Operating Instructions, 10/2014, A5E02630801-06...
  • Page 50 Dimension drawings 7.1 X-300M dimension drawings Figure 7-2 X308-2M drilling template SCALANCE X-300M Compact Operating Instructions, 10/2014, A5E02630801-06...
  • Page 51: Approvals

    Approvals X-300M approvals, certificates Approvals issued Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate.
  • Page 52 (http://support.automation.siemens.com/WW/view/en/27069465)", in "Further documentation". – "EMC Installation Guidelines" configuration manual ID = 60612658 (http://support.automation.siemens.com/WW/view/en/60612658) ● Working on the device To protect the device from electrostatic discharge, personnel must first discharge any electrostatic charge from their body before touching the device.
  • Page 53 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (http://support.automation.siemens.com/WW/view/en). Enter the document identification number C234 as the search term. SIMATIC NET products meet the requirements of the EC directive:94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres".
  • Page 54 Approvals 8.1 X-300M approvals, certificates The product meets the requirements of the standards: ● Factory Mutual Approval Standard Class Number 3611 ● FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 C-Tick The product meets the requirements of the AS/NZS 2064 standard (Class A).
  • Page 55: Declaration Of Conformity

    8.2 Declaration of conformity Declaration of conformity Declaration of conformity You will find the EC Declaration of Conformity for these products on the Internet at the following address: http://support.automation.siemens.com/WW/view/en/67218486 (http://support.automation.siemens.com/WW/view/en/67218486) --> Entry list --> Entry type "Certificates" --> Certificate type "Declaration of Conformity"...
  • Page 56: Overview Of X-300M Approvals

    Approvals 8.4 Overview of X-300M approvals Overview of X-300M approvals Table 8- 1 Overview of the approvals Device: (Variant) c-UL-us c-UL-us C-TICK ATEX95 SCALANCE for hazard- Zone 2 ous loca- tions X308-2M ● ● ● ● ● ● X308-2M TS ●...
  • Page 57: Index

    Index Glossary, 6 Hazardous area, 10 Possible attachments SCALANCE 308-2M, 14 Safety notices, 9 SIMATIC NET glossary, 6 System manual, 52 SCALANCE X-300M Compact Operating Instructions, 10/2014, A5E02630801-06...