Show Rec-Path - Fujitsu ETERNUS DX80 S2 Cli User's Manual

Disk storage systems
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 4 Function/System Settings and Display
4.2 Advanced Copy Management > show rec-path

show rec-path

This command is used to display the detailed REC path information of a system, and also displays the status of
any remotely connected devices. If this parameter is omitted, the information regarding all remote storage
systems is listed. If this parameter is specified, the path information for a single device can be displayed.
Syntax
show rec-path [-remote-boxid
Parameter
-remote-boxid
Output
When the parameter is omitted:
# Remote Storage System
# E Remote Box ID
#
#
00DXL#########ET06F21AUABCPJ000002######
# * 00DXL#########ET06F21AUABCPJ000004######
A B
A:
Error sign. If "*" mark is output, it means that path information status between storage systems is not normal.
You can check details by trying this command with this remote Box ID.
B:
Box ID of a remote storage system registered in the system
C:
Connection form of a remote storage system registered in the system
D:
Effective line speed of a remote storage system registered in the system
E:
Round trip time of a remote storage system registered in the system. If a round trip time is not measured,
`Unknown' is displayed.
F:
Actual multiplicity of a remote storage system registered in the system. If "Auto" is displayed, it indicates that a
recommended multiplicity is used.
G:
Multiplicity recommended by the system. If the round trip time is "Unknown", "***" is displayed.
H:
Copy revel of a remote storage system registered in the system. "auto" indicates that the EC/OPC rate is used.
I:
Copy Schedule Mode
remote_storage_box_id
Optional. This parameter specifies the Box ID of the storage system whose REC path
information details are to be displayed. Only one Box ID can be specified at a time. If this
parameter is omitted, a list of the storage system and its remote storage systems is displayed
Box IDs use a maximum of 40 alphanumeric characters, spaces, and pound key characters
(#).
All alphabetic characters are handled as uppercase.
The pound key characters (#) are automatically appended when the input characters are
less than 40.
Path Type
Direct
Switched
C
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
]
Line Speed
Round Trip
Multiplicity
(Mbit/s)
Time (ms)
Current / Recommended
-
-
-
10
20
D
E
F
424
Priority
Copy Schedule
Level
Mode
-
3
Session
4
3
-
Destination
G
H
I
P2X0-1030-09ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents