Set Event-Parameters - Fujitsu ETERNUS DX80 S2 Cli User's Manual

Disk storage systems
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 5 Information Settings and Display
5.4 Utility > set event-parameters

set event-parameters

This command specifies the notifications of an event other than the notifications specified in the "set event-
notification" command.
Syntax
set event-parameters [-blink-panel-led {enable | disable} ] [-redundant-copy-led {enable | disable}]
Parameter
-blink-panel-led
-redundant-copy-led
Example(s)
The following example sets the event parameters:
CLI> set event-parameters -blink-panel-led enable -redundant-copy-led enable
Optional. This parameter specifies whether the Panel FAULT LED will blink when the system is
in "warning" status.
enable
The Panel FAULT LED will blink.
disable
The Panel FAULT LED will not blink.
Optional. This parameter specifies whether the FAULT LED will turn on after the redundant
copy is complete.
enable
The Fault LED will turn on after the redundant copy is complete.
disable
The Fault LED will not turn on after the redundant copy is complete.
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED