Chapter 3 Configuration Settings and Display
3.5 Host Interface Management > set host-affinity

set host-affinity

This command associates affinity groups with host identifiers through an individual host interface port. This is
used to provide security from unauthorized access. The maximum number of host affinity definitions depends
on the number of available host interface ports and the system model.
Syntax
set host-affinity { -port xyz {-ag-number
-lg-number
{-host-number
{ -port-group-number
{ -ag-number
{ -host-group-number
-host-response-number
}
Parameter
-port
-ag-number
or
-ag-name
-lg-number
or
-lg-name
-host-number
or
-host-name
-port-group-number
or
-port-group-name
lg_numbers
lg_names
| -lg-name
host_numbers
| -host-name
port_group_number
ag_number
ag_name
| -ag-name
host_group_numbers
host_response_number
This parameter specifies the host interface port to associate affinity groups with host servers.
Two or more parameters can be specified by separating them with a comma.
Example: -port 000,100
For details, refer to
"1.2.14 Host Interface Port Syntax" (page
xyz
"x" is the controller module (CM) number, "y" is the CA number, and "z" is the host port
number.
Example: "123" indicates CM#1-CA#2-Host port#3
This parameter specifies the affinity group identifiers that will be associated. One or more
parameters can be specified at the same time. For details, refer to
Syntax" (page
24). If two or more affinity groups are specified, the associated host identifier
parameters must be specified in the same order.
This parameter specifies the LUN group identifiers that will be associated. One or more
parameters can be specified at the same time. For details, refer to
Syntax" (page
24). If two or more LUN groups are specified, the associated host identifier
parameters must be specified in the same order.
This parameter specifies the host identifiers to be associated. One or more parameters can be
specified at the same time. For details, refer to
host identifiers are specified, the affinity group identifier parameters must be specified in the
same order.
This parameter specifies the port group number or the port group name. Only one port group
can be specified at the same time. For details, refer to
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
ag_numbers
| -ag-name
ag_names
}
host_names
} |
port_group_name
| -port-group-name
lg_number
| -lg-number
host_group_names
| -host-group-name
| -host-response-name
"1.2.10 Host Syntax" (page
"1.2.15 Port Group Syntax" (page 26)
273
|
}
lg_name
| -lg-name
}
|
host_response_name
}
25).
"1.2.11 Affinity Group
"1.2.11 Affinity Group
23). If two or more
P2X0-1030-09ENZ0