Chapter 5 Information Settings and Display
5.1 Performance > set raid-tuning

set raid-tuning

This command the performance tuning parameters for the specified RAID group. For normal operations, the
performance tuning parameters do not need to be changed.
Syntax
set raid-tuning {-rg-number
[-dcmf {1|2|3|4|5|6|7|8|9|10}] [-rebuild-priority {low|middle|high}] [-disk-tuning {enable|disable}]
[-throttle {10|20|30|40|50|60|70|80|90|100}] [-ordered-cut {0-65535}]
Parameter
-rg-number
or
-rg-name
-dcmf
-rebuild-priority
-disk-tuning
-throttle
rg_numbers
This parameter specifies the RAID group identifiers whose tuning parameters are to be set up.
One or more parameters can be specified at the same time. For details, refer to
Group Syntax" (page
22).
Optional. This parameter specifies the value of Disk Command Multiplying Factor (DCMF).
DCMF is a coefficient that increases the limit on the number of outstanding disk commands.
Increasing the value of DCMF improves sequential write performance. The default value is one.
A DCMF value of two results in the limit on the number of outstanding commands by a factor of
two from the default.
Optional. This parameter specifies the priority for Rebuild of the relevant RAID group. The same
priority is set to all of the RAID groups that are specified with the "-rg-number" parameter or
the "-rg-name" parameter.
low
Low. Normal priority is given for rebuild, copyback, and redundant copy.
middle
Middle. Rebuild, copyback, and redundant copy are given the same priority as
host access.
high
High. Rebuild, copyback, and redundant copy are given priority over host access.
Optional. The default setting is "disabled". This parameter specifies whether to enable or
disable the tuning settings for disk accesses. If omitted, the existing setting is not changed.
When "disable" is specified, the "-throttle" and "-ordered-cut" parameters cannot be specified.
If omitted, the existing setting is not changed.
enable
The tuning settings are enabled.
disable
The tuning settings are disabled. (default)
Optional. This parameter specifies the ratio of command issues to disks as a percentage value.
This parameter can be specified only when "enable" is specified or is already set for the "-disk-
tuning" parameter. Between 10 and 100 (in increments of 10) can be specified. If omitted, the
existing setting is not changed.
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
rg_names