Fujitsu ETERNUS DX80 S2 Cli User's Manual page 697

Disk storage systems
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Appendix A Error Messages
Message
number
E0307
E0308
E0309
E0311
E0312
E0313
E0314
E0315
E0316
E0317
E0318
E0319
Syntax error in REC path information. (Missing double quotes)
A syntax error was detected in the specified REC path information file. Specifically, the specified operand
name is not enclosed in double quotations. Check the output line given in the details of this message .
Syntax error in REC path information. (Unexpected label)
A syntax error was detected in the specified REC path information file. Specifically, the specified label
names are mismatched. Check the output line given in the details of this message and amend it to the
correct label.
Syntax error in REC path information. (Undefined information)
A syntax error was detected in the specified REC path information file. Specifically, undefined information
was found. Check the output line given in the details of this message and amend it to match the defined
information.
Syntax error in REC path information. (Too many lines)
A syntax error was detected in the specified REC path information file. Specifically, the number of lines
used has reached its limit. Delete unnecessary lines.
Syntax error in REC path information. (Overlong line)
A syntax error was detected in the specified REC path information file. Specifically, the number of
characters used has reached its limit. Begin on a new line.
Syntax error in REC path information. (WWN does not match actual)
A syntax error was detected in the specified REC path information file. Specifically, an inappropriate WWN
was used. Check the output line given in the details of this message and amend it to the appropriate
WWN.
Syntax error in REC path information. (Host port mode does not match actual)
A syntax error was detected in the specified REC path information file. Specifically, an inappropriate host
interface port mode was used. Check the output line given in the details of this message and amend it to
the appropriate host interface port mode.
Syntax error in REC path information. (Number of storage-links for one storage system over upper limit)
A syntax error was detected in the specified REC path information file. Specifically, the number of path
information definitions for one storage system has reached its limit. Check the output line given in the
details of this message.
Syntax error in REC path information. (Number of storage-links between one pair of storage systems over
upper limit.)
A syntax error was detected in the specified REC path information file. Specifically, the number of path
information definitions between one pair of storage systems has reached its upper limit. Check the
output line given in the details of this message.
Syntax error in REC path information. (Number of port-links for one host interface port over upper limit)
A syntax error was detected in the specified REC path information file. Specifically, the number of path
information definitions for one host interface port has reached its limit. Check the output line given in the
details of this message.
Syntax error in REC path information. (Number of host interface ports for one storage system over upper
limit)
A syntax error was detected in the specified REC path information file. Specifically, the number of host
interface port definitions for one storage system has reached its limit. Check the output line given in the
details of this message.
Syntax error in REC path information. (Total number of storage systems over upper limit)
A syntax error was detected in the specified REC path information file. Specifically, the number of storage
system definitions has reached its limit. Check the output line given in the details of this message.
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED
Message
Countermeasure for the error
697
P2X0-1030-09ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents