Show Power-Synchronization - Fujitsu ETERNUS DX80 S2 Cli User's Manual

Disk storage systems
Hide thumbs Also See for ETERNUS DX80 S2:
Table of Contents

Advertisement

Chapter 4 Function/System Settings and Display
4.4 Miscellaneous > show power-synchronization

show power-synchronization

This command displays the settings that control how the shutdown function interacts with the external
sensor.
Syntax
show power-synchronization
Parameter
No parameters.
Output
# Controller Module #0
# Service Controller #0
# Controller Module #1
# Service Controller #1
# Auto Power
# Resume Power
# Waiting Time to Shutdown
# Type
# Power Fail Signal
# Low Battery Signal
# UPS Shutdown Signal
# UPS Shutdown
A:
It shows whether the CM#0 is connected to the power synchronized device. (This item is only displayed for the
ETERNUS DX80 S2/DX90 S2 and the ETERNUS DX410 S2/DX440 S2)
B:
It shows whether the SVC#0 is connected to the power synchronized device. (This item is only displayed for the
ETERNUS DX8700 S2)
C:
It shows whether the CM#1 is connected to the power synchronized device. (This item is displayed only for the
ETERNUS DX80 S2/DX90 S2 and the ETERNUS DX410 S2/DX440 S2)
D:
It shows whether the SVC#1 is connected to the power synchronized device. (This item is only displayed for the
ETERNUS DX8700 S2)
E:
The setting to turn the system power on when AC power is supplied.
F:
The setting to turn the system power on when AC power is supplied after the ETERNUS DX Disk storage system
is shutdown due to a power outage.
G:
The time that starts the ETERNUS DX Disk storage system shutdown when a power outage signal is received
from an external sensor device (This item is displayed only for the ETERNUS DX80 S2/DX90 S2).
H:
The reset interface (Power Synchronized Unit, PMAN, or manual). In this output, the preset interface is
displayed if the same setup as the preset is set by manual setup (This item is displayed only for the ETERNUS
DX80 S2/DX90 S2).
I:
The signal polarity that controls the input power outage signal when a power supply fails and power is not
provided (This item is displayed only for the ETERNUS DX80 S2/DX90 S2).
J:
The signal polarity that controls the battery voltage low signal when the battery usage of a UPS is low (This
item is displayed only for the ETERNUS DX80 S2/DX90 S2).
Enable
A
Enable
B
Disable
C
Disable
D
Enable
E
Disable
F
5 min.
G
Power Synchronized Unit
H
Positive
I
Negative
J
Negative
K
Enable
L
574
ETERNUS CLI User's Guide
Copyright 2015 FUJITSU LIMITED