4
?
Fp: To fuel pump
MAIN FUSE
Inspection
Check
the continuity
of EGI main fuse.
MAIN RELAY
Inspection
1. Turn ignition
switch ON and OFF, verify that the
main
relay "CLICKS"
2. If clicking
is not heard at main relay, check the con-
tinuity at terminals
using an ohmmeter,
and wiring
harness.
Continuity
1. Apply
12V to @I and a ground
@ terminals
of the
main relay.
2. Check continuity
at terminals
using an ohmmeter.
12V Not applied
IZV Applied
NO
Yes
NO
Yi?S
3. If not correct,
replace
it.
CIRCUIT OPENING RELAY
Inspection
Terminal
voltage
1, Check voltage
between
each terminal
and ground
using a voltmeter.
2. If not correct,
check
the resistance
using
the
ohmmeter.